CXA10-48D12 Emerson Network Power, CXA10-48D12 Datasheet - Page 2

CONVERTER DC/DC DUAL 12V OUT 10W

CXA10-48D12

Manufacturer Part Number
CXA10-48D12
Description
CONVERTER DC/DC DUAL 12V OUT 10W
Manufacturer
Emerson Network Power
Series
CXA10r
Type
Isolatedr
Datasheet

Specifications of CXA10-48D12

Rohs Status
RoHS non-compliant
Output
±12V
Number Of Outputs
2
Power (watts)
10W
Mounting Type
Through Hole
Voltage - Input
18 ~ 75V
Package / Case
6-DIP Module
1st Output
12 VDC @ 410mA
2nd Output
-12 VDC @ 410mA
Size / Dimension
2.00" L x 1.00" W x 0.39" H (50.8mm x 25.4mm x 10mm)
Power (watts) - Rated
10W
Operating Temperature
-40°C ~ 70°C
Efficiency
83%
Approvals
CSA, cUL, EN, UL, VDE
3rd Output
-
4th Output
-
Other names
393-1022

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CXA10-48D12-S
Manufacturer:
ARTESYN
Quantity:
1 000
Part Number:
CXA10-48D12-SY
Manufacturer:
artesyn
Quantity:
1 000
Part Number:
CXA10-48D12J
Manufacturer:
Emerson Network Power/Embedded
Quantity:
135
Part Number:
CXA10-48D12J
Manufacturer:
ARTESYN
Quantity:
1 000
Specifications
All specifications are typical at nominal input, full load at 25
OUTPUT SPECIFICATIONS
Voltage accuracy
Line regulation
(LL to HL)
Load regulation
(not incl. cross reg.)
Min. load
Ripple and noise
20 MHz bandwidth
Temperature coefficient
Overvoltage protection
Short circuit protection
Short <20 mΩ
Transient response
Load cross regulation
INPUT SPECIFICATIONS
Input voltage range
Input fuse
Max. input rise
and fall time
UVLO turn ON voltage
UVLO turn OFF voltage
Remote ON/OFF
Logic compatibility
ON
OFF
Singles/dual positives
Dual negatives
Full load to
minimum load
All outputs
3.3 V and 5.0 V
All others
All models
Clamp type
Hiccup
Min. load to FL
Min. load to FL (See Note 1)
48 Vin nominal
(See Note 10)
48 V ETS300 132-2
(See Note 5)
(See Note 5)
CMOS/TTL/Open Collector
(See table and Notes 3, 4)
auto. recovery
30 mV pk-pk
60 mV pk-pk
(See Note 7)
Open circuit
°
Continuous
12 mV rms
C unless otherwise stated.
±0.01%/°C
18-75 Vdc
1.5 A HRC
±0.15%
5 V/ms
<1 Vdc
±1.0%
±0.1%
±0.2%
±1.0%
±5.0%
10%
94%
86%
EMC CHARACTERISTICS
ETS 300 386-1 table 5
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge (500 V)
Fast transients
Radiated immunity
Conducted immunity
GENERAL SPECIFICATIONS
Efficiency
Isolation voltage
Switching frequency
Approvals and standards
(See Notes 7,8,9,10,11)
Material flammability
Weight
MTBF
(Representative model
48S05J @ 48 Vin)
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
ETS 300 019-2-3
Air temperature
Relative humidity
Vibration, Class 3M5
9-200 Hz 1 g
Shock, Class 3M5
EN55022 (See Note 6)
EN55022, external filter,
VDE0878, 48 V models
See Application Note 100
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3, 4
EN61000-4-4, level 3, 4
EN61000-4-3, level 3
EN61000-4-6, level 3
Input/output test voltage
Fixed
MIL-HDBK-217F
Parts stress method
Ground Benign @ 25 °C
Operating ambient
temperature
Non-operating
Low: IEC 68-2-1
High: IEC 68-2-2
Change: IEC 68-2-14
IEC 68-2-56
IEC 68-2-30
IEC68-2-6
MIL-STD-202F
IEC-68-2-29
MIL-STD-202F
Embedded Power for
Business-Critical Continuity
Method 213B cond. A
Method 204 cond. A
Classes T3.1 to T3.5
CSA C22.2 No. 950
2-9 Hz, 3 mm disp.
EN60950, UL1950
-55 °C to +105 °C
-40 °C to +70 °C,
10% to 100% RH
-40°C to +70 °C
456,621 hours
12 g (0.42 oz)
Condensation
See curves
1500 Vdc
See table
UL94V-0
400 kHz
Level A
Level B
+70 °C
-40 °C
Rev.12.04.07
cxa10
2 of 4

Related parts for CXA10-48D12