LQS80A48-1V8REJ Emerson Network Power, LQS80A48-1V8REJ Datasheet - Page 2

CONV DC/DC 144W 1.8V 80A SGL

LQS80A48-1V8REJ

Manufacturer Part Number
LQS80A48-1V8REJ
Description
CONV DC/DC 144W 1.8V 80A SGL
Manufacturer
Emerson Network Power
Series
Quarter-Brickr
Type
Isolated with Remote On/Off and UVLOr
Datasheet

Specifications of LQS80A48-1V8REJ

Output
1.8V
Number Of Outputs
1
Power (watts)
144W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
10-DIP Module, 1/4 Brick
1st Output
1.8 VDC @ 80A
Size / Dimension
2.30" L x 1.45" W x 0.34" H (58.4mm x 36.8mm x 8.64mm)
Power (watts) - Rated
144W
Operating Temperature
-40°C ~ 85°C
Efficiency
90%
Approvals
cUL, EN, UL, VDE
Output Power
144 W
Input Voltage Range
36 V to 75 V
Input Voltage (nominal)
48 V
Output Voltage (channel 1)
1.8 V
Output Current (channel 1)
80 A
Package / Case Size
2.3 in x 1.45 in x 0.34 in
Output Voltage
1.2 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1305
Electrical Specifications continued
EMC Characteristics
Immunity:
ESD air enclosure:
Radiated field enclosure:
Conducted:
Input transients:
General Characteristics
Basic insulation:
Switching frequency:
Approvals and standards:
Material flammability:
Weight:
MTBF:
Environmental Specifications
Thermal performance:
Protection
Short-circuit
Overvoltage
Thermal
EN61000-4-2 8 kV/6 kV (O/P within spec.)
EN61000-4-3 10 V/m (O/P within spec.)
EN61000-4-6 10 V (O/P within spec.)
100 V, 100 ms
Input/output
Fixed
(See Note 3)
Telcordia Tech SR-332
Operating ambient temperature
Non-operating
Continuous
Non-latching
125 ˚C hot spot temperature with automatic recovery
2250 Vdc
480 kHz
EN60950-1 VDE, UL/cUL 60950-1
UL94V-0
37g (1.30 oz)
3,866,933 hours
-40 ˚C to +85 ˚C
-55 ˚C to +125 ˚C
Embedded Power for
Business-Critical Continuity
Rev. 09.29.10
LQS Series
2 of 5

Related parts for LQS80A48-1V8REJ