24H1601-2R POWER ONE, 24H1601-2R Datasheet - Page 10

no-image

24H1601-2R

Manufacturer Part Number
24H1601-2R
Description
CONV DC-DC 50W 24VDC CASSETTE
Manufacturer
POWER ONE
Series
Hr
Type
Isolatedr
Datasheet

Specifications of 24H1601-2R

Output
24V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Surface Mount
Voltage - Input
14 ~ 30V
Package / Case
Module
1st Output
24 VDC @ 2A
Size / Dimension
6.63" L x 4.38" W x 1.52" H (168.5mm x 111.2mm x 38.7mm)
Power (watts) - Rated
50W
Operating Temperature
-10°C ~ 50°C
Efficiency
83%
Approvals
CE, cUL, TUV, UL
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
Q1166581
Electromagnetic Compatibility (EMC)
A suppressor diode together with an input filter form an
effective protection against input transient voltages which
typically occur in most installations, but especially in
Electromagnetic Emissions
Table 9: Emissions at V
Electromagnetic Immunity
Table 8: Immunity type tests
1
2
3
REV. MAR 27, 2006
Series
12H
24H
48H
Phenomenon
Electrostatic
discharge
(to case)
Electromagnetic IEC/EN
field
Electrical fast
transient/burst
Surge
Related and previous standards are referenced in: Technical Information: Standards .
i = input, o = output, c = case.
A = Normal operation, no deviation from specifications, B = Normal operation,temporary deviation from specs possible.
Standard
IEC/EN
61000-4-2
61000-4-3
IEC/EN
61000-4-4
IEC/EN
61000-4-5
-30 MHz
<A
<B
<B
CISPR 11/EN 55011, 1991
CISPR 22/EN 55022, 1987
i nom
1
and I
Standard
Level
2
1
1
x
o nom
contact discharge
direct, i/c, +i/–i
Coupling
antenna
mode
•30 MHz
+i/–i
i/c
<B
<B
<B
2
Page 10 of 19
applied
4000 V
20 V/m
500 V
500 V
Value
p
p
p
battery-driven mobile applications. The H series has been
successfully tested to the following specifications:
bursts of 5/50 ns
2.5 / 5 kHz over
period: 300 ms
50 Watt DC-DC Cassette Converters
15 ms; burst
Waveform
1.2/50 µs
AM 80%
1/50 ns
1 kHz
Source
imped.
330 Ω
50 Ω
12 Ω
n.a.
2 Ω
5 pos. and 5 neg.
H Series Data Sheet
26 to 1000 MHz
10 positive and
1 min negative
coupling mode
1 min positive
transients per
10 negative
procedure
discharges
surges per
Test
www.power-one.com
oper. form.
yes
yes
yes
yes
In
Per-
A
A
A
3

Related parts for 24H1601-2R