JFW100A Lineage Power, JFW100A Datasheet - Page 15

no-image

JFW100A

Manufacturer Part Number
JFW100A
Description
CONVERTER DC/DC 5V 100W OUT
Manufacturer
Lineage Power
Series
JFWr
Type
Isolatedr
Datasheet

Specifications of JFW100A

Output
5V
Number Of Outputs
1
Power (watts)
100W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
Module
1st Output
5 VDC @ 20A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
100W
Operating Temperature
-40°C ~ 100°C
Efficiency
84%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JFW100A81
Manufacturer:
TYCO
Quantity:
98
April 2008
Feature Descriptions
Forced Load Sharing (Parallel Operation)
(continued)
Good layout techniques should be observed for noise
immunity. To implement forced load sharing, the follow-
ing connections must be made:
n
n
n
Figure 26. Wiring Configuration for Redundant
Output Current Monitor
The current monitor (CURMON) pin produces a dc volt-
age proportional to the dc output current of the module.
The voltage is referenced to the secondary SENSE(–)
pin and is typically 4.10 V at rated output current. For
paralleling with FW300x modules, consult the factory
for the V/A ratio. The output impedance of this pin is
approximately 20 k¾, so customer detection circuitry
must have a high-impedance input.
Lineage Power
The parallel pins of all units must be connected
together. The paths of these connections should be
as direct as possible.
All remote-sense pins must be connected to the
power bus at the same point. That is, connect all
remote-sense (+) pins to the (+) side of the power
bus at the same point, and connect all remote-sense
(–) pins to the (–) side of the power bus at the same
point. Close proximity and directness are necessary
for good noise immunity.
Add a 1000 pF capacitor across the PARALLEL pin
and SENSE(–) pin of each module. Locate the
capacitor as close to the module as possible.
Parallel Operation
CASE
ON/OFF
V
V
CASE
ON/OFF
V
V
I
I
I
I
(+)
(–)
(+)
(–)
PARALLEL
PARALLEL
SENSE(+)
SENSE(–)
SENSE(+)
SENSE(–)
V
V
V
V
O
O
O
O
dc-dc Converters; 36 to 75 Vdc Input, 5 Vdc Output; 50 W to 150 W
(+)
(–)
(+)
(–)
(continued)
8-581 (C).c
Overtemperature Protection
These modules feature an overtemperature protection
circuit to safeguard against thermal damage. The cir-
cuit shuts down and latches off the module when the
maximum case temperature is exceeded. The module
can be restarted by cycling the dc input power for at
least 1.0 second or by toggling the primary or second-
ary referenced remote on/off signal for at least
1.0 second.
Power Good Signal
The power good signal (PWRGOOD pin) is an open-
collector, secondary-referenced pin that is pulled low
when all five of the following conditions are met:
1. The sensed output voltage is greater than half the
2. The overvoltage shutdown latch is not set.
3. The thermal shutdown latch is not set.
4. The unit is not in current limit.
5. Secondary internal bias is present.
There is one situation where the power good signal can
be low even though the module has failed. This can
occur when the module is paralleled with other mod-
ules for additional output power (i.e., the output ORing
diodes would not be used). If one module power train
stops delivering power (fails), the other paralleled mod-
ule(s) would provide a voltage at the output pin of the
failed module. The failed module would then not detect
that its output power is not being delivered. However, in
this situation, the current monitor pins of the paralleled
modules would indicate that current is not being deliv-
ered from one module and that module had failed.
For redundant applications, the ORing diodes would
keep the other module voltages from being applied to
the failed module output and the power good signal
would indicate a failure.
Thermal Warning Signal
The thermal warning (TEMPWARN) pin is a second-
ary-referenced, open-collector output that shorts to
SENSE(–) a few degrees before the module goes into
thermal shutdown. When the module temperature
cools, the thermal warning pin will open, but the unit
will remain latched off until the input power or the pri-
mary or secondary referenced remote on/off is recycled
for 1.0 second.
rated nominal output voltage.
15