MW005AJ Lineage Power, MW005AJ Datasheet - Page 2

no-image

MW005AJ

Manufacturer Part Number
MW005AJ
Description
CONVERTER DC/DC +-5V 5W OUT
Manufacturer
Lineage Power
Series
MW005r
Type
Isolatedr
Datasheet

Specifications of MW005AJ

Output
±5V
Number Of Outputs
2
Power (watts)
5W
Mounting Type
Through Hole
Voltage - Input
36 ~ 72V
Package / Case
5-DIP Module
1st Output
5 VDC @ 500mA
2nd Output
-5 VDC @ 500mA
Size / Dimension
2.00" L x 1.10" W x 0.46" H (50.8mm x 27.9mm x 11.7mm)
Power (watts) - Rated
5W
Operating Temperature
-40°C ~ 85°C
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MW005AJ
Manufacturer:
NIEC
Quantity:
1 000
Part Number:
MW005AJ4
Manufacturer:
LUCENT
Quantity:
32
Part Number:
MW005AJ4
Manufacturer:
TYCO
Quantity:
334
MW005-Series Power Modules:
36 Vdc to 75 Vdc Inputs; 5 W
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply to all devices over all operating input voltage, resistive load, and
temperature conditions.
Table 1. Input Specifications
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal
fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse.
The safety agencies require a normal-blow fuse with a maximum rating of 5 A in series with the input (see Safety
Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc
input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for fur-
ther information.
2
Input Voltage:
Operating Ambient Temperature
Storage Temperature
I/O Isolation Voltage
Operating Input Voltage
Maximum Input Current
Inrush Transient
Input Reflected-ripple Current, Peak-to-peak
Input Ripple Rejection (120 Hz)
(0.30 ms
(V
(5 Hz to 20 MHz, 12 µH source impedance,
T
Considerations section.)
Continuous
Transient (2 ms)
A
I
= 25 °C, see Figure 24 and Design
= 0 V to 75 V; I
–1
(60 ft./min.) natural convection)
Parameter
O
= I
Parameter
O, max
; see Figure 1.)
Device
All
All
All
All
All
Symbol
I
I, max
I
V
2
I
I
I
t
Symbol
V
T
I, trans
T
V
stg
A
I
Min
36
Min
–40
–40
Typ
0.3
48
30
53
Tyco Electronics Corp.
Max
100
100
500
80
85
Max
600
1.0
75
Data Sheet
April 1999
Unit
Vdc
Vdc
mAp-p
°C
°C
V
Unit
Vdc
A
mA
dB
2
s