BXA40-48T05-12-M Emerson Network Power, BXA40-48T05-12-M Datasheet - Page 2

no-image

BXA40-48T05-12-M

Manufacturer Part Number
BXA40-48T05-12-M
Description
CONV DC/DC TRPL 5VOUT 40W METRIC
Manufacturer
Emerson Network Power
Series
BXA40r
Type
Isolatedr
Datasheet

Specifications of BXA40-48T05-12-M

Rohs Status
RoHS non-compliant
Output
5V, ±12V
Number Of Outputs
3
Power (watts)
40W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
5 VDC @ 6A
2nd Output
12 VDC @ 400mA
3rd Output
-12 VDC @ 400mA
Size / Dimension
2.20" L x 2.20" W x 0.50" H (55.9mm x 55.9mm x 12.7mm)
Power (watts) - Rated
40W
Operating Temperature
-40°C ~ 105°C
Efficiency
83%
Approvals
CE, CSA, EN, UL, VDE
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BXA40-48T05-12-M
Manufacturer:
IXYS
Quantity:
1 000
Part Number:
BXA40-48T05-12-M
Quantity:
134
BXA40 Series
Notes
1
2
3
4
5
6
7
8
9
10
11
International Safety Standard Approvals
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Please consult our website for the following items:
DC/DC CONVERTERS
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Nominal line, at no load.
Nominal line to high line, nominal line to low line.
Load regulation:
Main output (V1): 25 to 100% with 25% to 100% balanced on auxiliaries.
Auxiliary outputs (V2 and V3): 25% to 100% balanced on all outputs.
Cross regulation:
Main output 100% load, auxiliary 100%, other auxiliary 25% to 100%.
Auxiliary outputs (V2 and V3): main output 100% load, auxiliary 100%,
other auxiliary 25% to 100% or main output 25%, auxiliary 25%, other
auxiliary 25% to 100%.
Short circuit protection,
For EMI compliance to EN55022 level B please consult factory for details.
For EMI compliance to EN55022 level A, refer to BXA40 Design Note 101.
Reverse voltage protection, refer to BXA40 Design Note 101.
The maximum operating ambient temperature, without derating depends
on internal power dissipation and module efficiency and cooling method.
Download BXA40 Design Note 101 which provides detailed thermal
calculations and design-in hints from the Artesyn website.
It is suggested that an external filter capacitor be used. A 4µF (or greater)
film capacitor such as: ITW Paktron Capstick series, part number
405K100CS4 4µF/100V is recommended, if filtering is not used. See BXA40
Design Note 101.
The unit with the suffix ‘-M’ at the end of the model number is offered as
standard with metric threaded inserts (M3). To order a unit with imperial
threaded inserts (4-40 UNC) please remove the suffix ‘-M’ from the model
number. These inserts are used for bolting the unit to a
PCB and/or fixing heatsinks.
A top mounted heatsink kit is available for the BXA40.
The heatsink may be oriented parallel to or
perpendicular to the direction of the pins, thus providing
optimum flexibility for cooling requirements. The order
number for the top mounted heatsink kit with metric
screws is ‘NFC40-HTSK-T’. The order number for the
top mounted heatsink kit with imperial screws is
‘NFC40-HTSK-T-I’.
36-75VDC
VOLTAGE
VDE0805/EN60950/IEC950 File No. 14501-3336-7009
Licence No. 6296
UL1950 File No. E174104
CSA C22.2 No. 950 File No. LR41062C
INPUT
VOLTAGE
OUTPUT
5V/±12V
1 minute on auxiliary outputs.
T r i p l e o u t p u t
40W Wide Input DC/DC Converters
CURRENT (MAX.)
6A/±0.4A
OUTPUT
Design Note
(12.70)
0.50
Imperial (No '-M' suffix) 4-
0.019
(0.50)
M3 Tap Thru. 4 places or
0.043 0.003(1.02 0.05)
Diameter Typ.
0.256 (6.50) Diameter
(3.90)
0.15
Stand-off (4 Places)
CURRENT
Metric (Suffix '-M'):
40 UNC (Optional)
INPUT
30mA
(3.82)
0.15
(1)
PIN NUMBER
ALL DIMENSIONS IN INCHES (mm)
1
2
3
4
5
6
7
8
9
9
EFFICIENCY
(31.76)
1.25
TOLERANCE :
(Unless otherwise specified)
PIN CONNECTIONS
3
8
TYPICAL
(20.32)
BOTTOM VIEW
0.8
(15.24)
83%
(15.24)
0.60
(48.26)
0.6
1.90
7
2.20 0.02
(55.90 0.50)
(7.62)
2
0.3
6
1
(12.70)
5
(2.54)
0.5
(5.08)
0.1
0.2
0.004 (0.1)
File Name: BXA40T.PDF Rev: 02 Oct 2002
4
(5.08)
www.artesyn.com
0.2
TRIPLE OUTPUT
MODEL NUMBER
No Connection
BXA40-48T05-12-M
+ Output (V2)
+ Output (V1)
- Output (V3)
- Output (V1)
Common
+ Input
Control
– Input
(45.72)
1.80
(1.27)
0.05
(48.26)
0.15
(3.82)
1.90
2.20 0.02
(55.90 0.50)
(10)
2

Related parts for BXA40-48T05-12-M