Page 1
Data Sheet December 18, 2009 Austin Lynx 18/20-30/32Vdc input 6Vdc & 15Vdc Output; 30/50W RoHS Compliant Applications Distributed power architectures Intermediate bus voltage applications Telecommunications equipment Wireless Base stations Industrial equipment LANs/WANs Enterprise Networks Latest generation ...
Page 2
Data Sheet December 18, 2009 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or ...
Page 3
Data Sheet December 18, 2009 Electrical Specifications (continued) Parameter Output Voltage Set-point ( =25° min O O, max A Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until ...
Page 4
Data Sheet December 18, 2009 Electrical Specifications (continued) Parameter Dynamic Load Response (dI /dt=5A/μ =25° nom A Load Change from Io= 50% to 100 external output capacitors Peak Deviation (Vo = ...
Page 5
Data Sheet December 18, 2009 Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter On/Off Signal interface (On/Off is open collector/drain logic input; Signal referenced ...
Page 6
Data Sheet December 18, 2009 Characteristic Curves The following figures provide typical characteristics for the AXB030X module at 3.3V, 10A and Vin=24V 80 Vin=30V OUTPUT CURRENT, I Figure 1. onverter Efficiency ...
Page 7
Data Sheet December 18, 2009 Characteristic Curves (continued) The following figures provide typical characteristics for the AXB050X module at 5V, 8A and 25 100 Vin=24V 80 Vin=30V OUTPUT CURRENT, I Figure 7. ...
Page 8
Data Sheet December 18, 2009 Characteristic Curves (continued) The following figures provide typical characteristics for the AXB050X module at 12V, 4A and 25 100 95 90 Vin=24V 85 80 Vin=30V OUTPUT CURRENT, I Figure 13. ...
Page 9
Data Sheet December 18, 2009 Characteristic Curves (continued) The following figures provide typical characteristics for the AXB050X module at 15V, 3A and 25 100 Vin=30V 0.5 1 1.5 OUTPUT CURRENT, I Figure 19. ...
Page 10
Data Sheet December 18, 2009 Test Configurations TO OSCILLOSCOPE L TEST 1μ 220μF S Min E.S.R.<0.1Ω 150μF @ 20°C 100kHz NOTE: Measure input reflected ripple current with a simulated source inductance ( 1μH. Capacitor C ...
Page 11
Data Sheet December 18, 2009 Feature Description Remote On/Off TM The Austin Lynx 24V SMT power modules feature an On/Off pin for remote On/Off operation. Positive Logic On/Off signal, device code suffix “4”, turns the module ON during a logic ...
Page 12
... Design Tools section, also calculates the values of R and R for a specific output margin-up margin-down voltage and % margin. Please consult your local Lineage Power technical representative for additional details. LINEAGE POWER TM Austin Lynx 24V: Non-isolated Power Modules: 18/20– 30/32Vdc input; 3 – 6Vdc & 5 – 15Vdc Output; 30/50W ...
Page 13
Data Sheet December 18, 2009 Thermal Considerations Power modules operate in a variety of thermal environments; however, sufficient cooling should always be provided to help ensure reliable operation. Considerations include ambient temperature, airflow, module power dissipation, and the need for ...
Page 14
Data Sheet December 18, 2009 Mechanical Outline Dimensions are in millimeters and (inches). Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated] x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.) Non Co-planarity (max): ...
Page 15
Data Sheet December 18, 2009 Recommended Pad Layout Dimensions are in millimeters and (inches). Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated] x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.) LINEAGE POWER ...
Page 16
Data Sheet December 18, 2009 Packaging Details TM The Austin Lynx 24V SMT versions are supplied in tape & reel as standard. Modules are shipped in quantities of 250 modules per reel. Tape Dimensions Reel Dimensions Outside diameter: 330.2 mm ...
Page 17
... Oblong or oval nozzles may also be used within the space available. For further information please contact your local Lineage Power technical representative. Tin Lead Soldering TM The Austin Lynx 24V SMT power modules are lead ...
Page 18
Data Sheet December 18, 2009 Surface Mount Information Lead Free Soldering The –Z version Austin Lynx 24V SMT modules are lead-free (Pb-free) and RoHS compliant and are both forward and backward compatible in a Pb-free and a SnPb soldering process. ...
Page 19
... Table 1. Device Codes Input Device Code Voltage Range AXB030X43-SR 18 – 30Vdc AXB030X43-SRZ 18 – 30Vdc AXB050X43-SR 20 – 32Vdc AXB050X43-SRZ 20 – 32Vdc -Z refers to RoHS-compliant codes World Wide Headquarters Lineage Power Corporation 601 Shiloh Road, Plano, TX 75074, USA +1-800-526-7819 (Outside U.S.A.: +1-972-244-9428) www.lineagepower.com e-mail: techsupport1@lineagepower.com Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice ...