Specifications of GS-R424

Output
24V
Number Of Outputs
1
Power (watts)
96W
Mounting Type
Through Hole
Voltage - Input
28 ~ 46V
Package / Case
Module
1st Output
24 VDC @ 4A
Size / Dimension
3.37" L x 2.64" W x 0.84" H (85.5mm x 67mm x 21.3mm)
Power (watts) - Rated
96W
Operating Temperature
-20°C ~ 85°C
Efficiency
90%
Output Voltage
24 V
Operating Temperature Range
- 20 C to + 85 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
497-8275
GS-R424

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
GS-R424
Manufacturer:
NEC
Quantity:
2 300
Part Number:
GS-R424
Manufacturer:
ST
0
Part Number:
GS-R424/2
Manufacturer:
ST
0
GS-R400 FAMILY
CONNECTION DIAGRAM AND MECHANICAL DATA
PIN DESCRIPTION
2/5
Pin
10
12
11
Dimensions in mm
1
2
3
4
5
6
7
8
9
Inhibit
Reset
+ Input
Input GND
Oscillator
Sync
Current limiting
Output GND
– Sense
+ Sense
+ Output
Program
Function
The module is disabled by a high logic level applied to this pin.
Reset output (GS-R405S only).
DC input voltage. Recommended maximum voltage is 46V.
Return for input voltage source.
100kHz oscillator output. To be connected to Sync (pin 6) input if the unit is a master and
left open if it is a slave (GS-R400VB only). See fig. 5.
Synchronization input. To be connected to the Oscillator output (pin 5) of the master (GS-
R400VB only). See fig. 5.
A resistor ( 2.2k ) connected from this pin to pin 9 sets the current limiting level
(GS-R400VB only).
Return for output current path.
Internally connected to pin 4.
Senses the remote load return. Must be tied to pin 8 when the remote sensing feature is
not used. See fig. 1.
Senses the remote load high side. Must be tied to pin 11 when the remote load sensing
feature is not used. See fig. 1.
Regulated DC output voltage.
A resistor ( 18k ) connected between this pin and pin 10 sets the output voltage
(GS-R400V and GS-R400VB only).
Bottom view
Description
Pin 2
Pin 5,6,7 GS-R400VB only
Pin 12
GS-R405S only
GS-R400V/VB only