OKL-T/6-W12N-C Murata Power Solutions Inc, OKL-T/6-W12N-C Datasheet
OKL-T/6-W12N-C
Specifications of OKL-T/6-W12N-C
Related parts for OKL-T/6-W12N-C
OKL-T/6-W12N-C Summary of contents
Page 1
... The OKL-T/6-W12 series are miniature non-iso- lated Point-of-Load (PoL) DC/DC power converters for embedded applications. Featuring inspectable Land Grid Array (iLGA) format, the OKL-T/6-W12 measures only 0.48 x 0.48 x 0.283 inches max. (12.2 x 12.2 x 7.2 mm max.). The wide input range is 4 Volts DC. ...
Page 2
... Input Voltage Range 4.5-14Vdc Maximum Rated Output Current in Amps OKL-T/6-W12P-C OKL-T/6-W12N-C OKL2-T/6-W12P-C OKL2-T/6-W12N-C The manufacturing date code is four characters: First character – Last digit of manufacturing year, example 2009 Second character – Month code (1 through 9 and O through D) Third character – Day code (1 through 10=O and 11 through through Z) Fourth character – ...
Page 3
... V. to +15 Volts max min. to +14V max. None, install external fuse Current-limited. Devices can withstand a sustained short circuit without damage. The outputs are not intended to accept appreciable reverse current. -55 to +125 °C. See soldering specifi cations email: sales@murata-ps.com MDC_OKL-T/6-W12 Series.A08 Page ...
Page 4
... This short current pulse prevents overheating and damaging the converter. Once the fault is removed, the converter immediately recovers normal operation. www.murata-ps.com 28 Mar 2011 OKL-T/6-W12 Series email: sales@murata-ps.com MDC_OKL-T/6-W12 Series.A08 Page ...
Page 5
... Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 1˚ Components are shown for reference only. email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/6-W12 Series.A08 Page Function V IN Ground V OUT Sense Trim Ground Third Angle Projection ...
Page 6
... Pocket tape length before modules C Cover tape length before pocket tape www.murata-ps.com OKL-T/6-W12 Series Programmable Output 6-Amp iLGA SMT PoLs 7.40±0.1 0.40±0.05 Start of pocket tape C B Start of cover tape Length (mm) email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/6-W12 Series.A08 Page 800 ±40 200 min. 240 ±40 ...
Page 7
... Output Ripple and Noise (Vin=12V, Vout=5.0V, Iout=6A, Cload=0, ScopeBW=20MHz) Step Load Transient Response (Vin=12V, Vout=5.0V, Cload=0, Iout=6A to 3A) www.murata-ps.com OKL-T/6-W12 Series 65 LFM 100 LFM Ambient Temperature (ºC) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2A/div. email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/6-W12 Series.A08 Page ...
Page 8
... Output Ripple and Noise (Vin=12V, Vout=3.3V, Iout=6A, Cload=0, ScopeBW=20MHz) Step Load Transient Response (Vin=12V, Vout=3.3V, Cload=0, Iout=6A to 3A) www.murata-ps.com OKL-T/6-W12 Series 65 LFM 100 LFM Ambient Temperature (ºC) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2A/div. email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/6-W12 Series.A08 Page ...
Page 9
... Output Ripple and Noise (Vin=12V, Vout=2.5V, Iout=6A, Cload=0, ScopeBW=20MHz) Step Load Transient Response (Vin=12V, Vout=2.5V, Cload=0, Iout=6A to 3A) www.murata-ps.com OKL-T/6-W12 Series 65 LFM 100 LFM Ambient Temperature (ºC) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2A/div. email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/6-W12 Series.A08 Page ...
Page 10
... Output Ripple and Noise (Vin=12V, Vout=1.8V, Iout=6A, Cload=0, ScopeBW=20MHz) Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=0, Iout=6A to 3A) www.murata-ps.com OKL-T/6-W12 Series 65 LFM 100 LFM Ambient Temperature (ºC) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2A/div. email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/6-W12 Series.A08 Page ...
Page 11
... Output Ripple and Noise (Vin=12V, Vout=1.2V, Iout=6A, Cload=0, ScopeBW=20MHz) Step Load Transient Response (Vin=12V, Vout=1.2V, Cload=0, Iout=6A to 3A) www.murata-ps.com OKL-T/6-W12 Series 65 LFM 100 LFM Ambient Temperature (ºC) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2A/div. email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/6-W12 Series.A08 Page ...
Page 12
... Output Ripple and Noise (Vin=12V, Vout=1.0V, Iout=6A, Cload=0, ScopeBW=20MHz) Step Load Transient Response (Vin=12V, Vout=1.0V, Cload=0, Iout=6A to 3A) www.murata-ps.com OKL-T/6-W12 Series 65 LFM 100 LFM Ambient Temperature (ºC) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2A/div. email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/6-W12 Series.A08 Page ...
Page 13
... Output Ripple and Noise (Vin=12V, Vout=.591V, Iout=6A, Cload=0, ScopeBW=20MHz) Step Load Transient Response (Vin=12V, Vout=.591V, Cload=0, Iout=6A to 3A) www.murata-ps.com OKL-T/6-W12 Series 65 LFM Ambient Temperature (ºC) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2A/div. email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/6-W12 Series.A08 Page ...
Page 14
... The converter will operate with no additional external capacitance if these conditions are met. www.murata-ps.com 28 Mar 2011 OKL-T/6-W12 Series email: sales@murata-ps.com MDC_OKL-T/6-W12 Series.A08 Page ...
Page 15
... CAUTION: These graphs are all collected at slightly above Sea Level altitude. Be sure to reduce the derating for higher density altitude. www.murata-ps.com OKL-T/6-W12 Series COPPER STRIP SCOPE C1 C2 COPPER STRIP C1 = 1μF CERAMIC C2 = 10μF CERAMIC LOAD 2-3 INCHES (51-76mm) FROM MODULE email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/6-W12 Series.A08 Page LOAD ...
Page 16
... Soaking Zone time above 217° C 45-75 sec 120 sec max High trace = normal upper limit Preheating Zone Low trace = normal lower limit 240 sec max 90 120 150 180 210 240 270 Time (sec) email: sales@murata-ps.com MDC_OKL-T/6-W12 Series.A08 Page 5.5 300 ...
Page 17
... The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. www.murata-ps.com/locations OKL-T/6-W12 Series © 2011 Murata Power Solutions, Inc. email: sales@murata-ps.com 28 Mar 2011 MDC_OKL-T/6-W12 Series.A08 Page ...