APTS006A0X4-SRZ Lineage Power, APTS006A0X4-SRZ Datasheet - Page 18

no-image

APTS006A0X4-SRZ

Manufacturer Part Number
APTS006A0X4-SRZ
Description
CONVER DC-DC 0.59 5.5V @ 6A SMD
Manufacturer
Lineage Power
Series
Pico TLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of APTS006A0X4-SRZ

Output
0.59 ~ 5.5V
Number Of Outputs
1
Power (watts)
33W
Mounting Type
Surface Mount
Voltage - Input
4.5 ~ 14V
Package / Case
10-SMD Module
1st Output
0.59 ~ 5.5 VDC @ 6A
Size / Dimension
0.48" L x 0.48" W x 0.29" H (12.2mm x 12.2mm x 7.3mm)
Power (watts) - Rated
33W
Operating Temperature
-40°C ~ 85°C
Efficiency
91%
Approvals
CSA, EN, UL, VDE
Output Current
6A
Input Voltage
4.5 to 14V
Screening Level
Industrial
Mounting Style
Surface Mount
Pin Count
10
Product
Non-Isolated / POL
Output Power
33 W
Input Voltage Range
4.5 V to 14 V
Output Voltage (channel 1)
0.59 V to 5.5 V
Output Current (channel 1)
6 A
Output Type
Non-Isolated
Output Voltage
0.59 V to 5.5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Compliant
Other names
555-1146-2
CC109126034

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
APTS006A0X4-SRZ
Quantity:
25
Data Sheet
November 22, 2010
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should
always be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up
is shown in Figure 49. The preferred airflow direction
for the module is in Figure 50.
The thermal reference points, T
specifications are also shown in Figure 50. For reliable
operation the temperatures at these points should not
exceed 120
not exceed the rated power of the module (Vo,set x
Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
LINEAGE
Wind Tunnel
PWBs
POWER
Figure 49. Thermal Test Setup.
o
C. The output power of the module should
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
4.5 – 14Vdc input; 0.59Vdc to 5.5Vdc output; 6A output current
ref
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
12V Pico TLynx
used in the
TM
Figure 50. Preferred airflow direction and location
of hot-spot of the module (Tref).
Modules marked ruggedized with a “D” suffix operate
up to an ambient of 105°C. For the remaining types
de-rating curves for individual output voltages meet
existing specifications up to 85°C.
6A: Non-isolated DC-DC Power Modules
18

Related parts for APTS006A0X4-SRZ