APXW005A0X3-SRZ Lineage Power, APXW005A0X3-SRZ Datasheet - Page 15

PWR MOD DC/DC NON-ISOL 9-36V 5A

APXW005A0X3-SRZ

Manufacturer Part Number
APXW005A0X3-SRZ
Description
PWR MOD DC/DC NON-ISOL 9-36V 5A
Manufacturer
Lineage Power
Series
ProLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of APXW005A0X3-SRZ

Output
3 ~ 18V
Number Of Outputs
1
Power (watts)
90W
Mounting Type
Surface Mount
Voltage - Input
9 ~ 36V
Package / Case
7-SMD Module
1st Output
3 ~ 18 VDC @ 5A
Size / Dimension
0.80" L x 0.45" W x 0.34" H (20.3mm x 11.4mm x 8.5mm)
Operating Temperature
-40°C ~ 85°C
Efficiency
95.9%
Approvals
CSA, EN, UL, VDE
Input Voltage Range
9 V to 36 V
Output Voltage (channel 1)
3 VDC to 18 VDC
Output Current (channel 1)
2.5 A to 5 A
Package / Case Size
20.3 mm x 11.4 mm x 8.5 mm
Output Type
Non-Isolated
Output Voltage
3 VDC to 18 VDC
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1172-2
CC109151916

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
APXW005A0X3-SRZ
Manufacturer:
GENERGY
Quantity:
120
Part Number:
APXW005A0X3-SRZ
Manufacturer:
GEENER
Quantity:
20 000
Company:
Part Number:
APXW005A0X3-SRZ
Quantity:
750
Preliminary Data Sheet
October 28, 2010
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should always
be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up
is shown in Figure 39. The preferred airflow direction
for the module is in Figure 40. The derating data
applies to airflow in either direction of the module’s short
axis.
LINEAGE
Wind Tunnel
PWBs
POWER
Figure 39. Thermal Test Setup.
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
9 – 36Vdc input; 3Vdc to 18Vdc output; 5A to 2.5A output current
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
9-36V ProLynx
The thermal reference points, T
specifications are also shown in Figure 40. For reliable
operation the temperatures at these points should not
exceed 115
not exceed the rated power of the module (Vo,set x
Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
Figure 40. Preferred airflow direction and location of
hot-spot of the module (Tref).
TM
5A: Non-isolated DC-DC Power Modules
o
C. The output power of the module should
ref
used in the
15

Related parts for APXW005A0X3-SRZ