ATH030A0X3Z Lineage Power, ATH030A0X3Z Datasheet - Page 16

CONVER DC/DC 0.8 3.63V @ 30A SIP

ATH030A0X3Z

Manufacturer Part Number
ATH030A0X3Z
Description
CONVER DC/DC 0.8 3.63V @ 30A SIP
Manufacturer
Lineage Power
Series
Austin MegaLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of ATH030A0X3Z

Output
0.8 ~ 3.63V
Number Of Outputs
1
Power (watts)
108W
Mounting Type
Through Hole
Voltage - Input
4.5 ~ 5.5V
Package / Case
13-SIP Module
1st Output
0.8 ~ 3.63 VDC @ 30A
Size / Dimension
2.00" L x 0.55" W x 0.50" H (50.8mm x 14mm x 12.7mm)
Power (watts) - Rated
108W
Operating Temperature
-40°C ~ 85°C
Efficiency
93%
Approvals
CSA, EN, UL, VDE
Product
Non-Isolated / POL
Output Power
109 W
Input Voltage Range
4.5 V to 5.5 V
Output Voltage (channel 1)
0.8 V to 3.63 V
Output Current (channel 1)
30 A
Package / Case Size
SIP
Output Type
Non-Isolated
Output Voltage
0.8 V to 3.63 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1094
CC109104782
Wind Tunnel
Data Sheet
October 2, 2009
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should always
be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of the
module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up is
shown in Figure 47. Note that the airflow is parallel to
the long axis of the module as shown in Figure 48. The
derating data applies to airflow in either direction of the
module’s long axis.
Figure 47. Thermal Test Set-up.
LINEAGE
PWBs
POWER
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
4.5 – 5.5Vdc input; 0.8 – 3.63Vdc output; 30A output current
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
6.0 – 14Vdc input; 0.8 – 5.5Vdc output; 25A output current
Austin MegaLynx
Figure 48. T ref Temperature measurement location.
The thermal reference point, T
specifications is shown in Figure 48. For reliable
operation this temperature should not exceed 125
The output power of the module should not exceed the
rated power of the module (Vo,set x Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
TM
: Non-Isolated DC-DC Power Modules:
Back View
ref
used in the
16
o
C.

Related parts for ATH030A0X3Z