VRAH-12F1200 Bel Fuse Inc, VRAH-12F1200 Datasheet
VRAH-12F1200
Specifications of VRAH-12F1200
Related parts for VRAH-12F1200
VRAH-12F1200 Summary of contents
Page 1
... = Typical Part Number Efficiency Surface Mount 93% SRAH-12F330 89% SRAH-12F250 87% SRAH-12F180 84% SRAH-12F150 82% SRAH-12F120 80% SRAH-12F100 Max Notes °C 125 °C Max Notes 5.5 V 5.5 V 5.5 V 200 10.5 A 9.0 A 8.1 A 6 Part Number Vertical Mount VRAH-12F330 VRAH-12F250 VRAH-12F180 VRAH-12F150 VRAH-12F120 VRAH-12F100 ...
Page 2
... Overshoot 100% ~ 50% Max Load Settling Time Note: All specifications are typical input, full load at 25 Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com 1.0 Vdc - 3.3 Vdc/12 A Output Min Typ Max ...
Page 3
... Remote On/Off Signal Low (Unit Off) 2.1 V (Vin=3.0 V) Signal High (Unit On) 3.15 V (Vin=4.5 V) 3.85 V (Vin=5.5 V) Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com 1.0 Vdc - 3.3 Vdc/12 A Output Min Typ 90% 93% ...
Page 4
... Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com 1.0 Vdc - 3.3 Vdc/12 A Output − adj − D nom A B 161.900 208 ...
Page 5
... Output Current (A) xRAH-12F120 Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com 1.0 Vdc - 3.3 Vdc/12 A Output 4.5 V 5 92.00% 90.00% 88.00% 86.00% 84.00% 3 ...
Page 6
... NON-ISOLATED DC/DC CONVERTERS 3.0 Vdc - 5.5 Vdc Input Thermal Derating Curves SRAH-12F330 SRAH-12F250 SRAH-12F180 Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com 1.0 Vdc - 3.3 Vdc/12 A Output VRAH-12F330 VRAH-12F250 VRAH-12F180 ...
Page 7
... Vdc - 5.5 Vdc Input Thermal Derating Curves (continued) SRAH-12F150 SRAH-12F120 SRAH-12F100 Test Condition: Derating curves are tested input. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com 1.0 Vdc - 3.3 Vdc/12 A Output VRAH-12F150 VRAH-12F120 VRAH-12F100 ...
Page 8
... Vdc Input, 1.8 Vdc Output 3.3 Vdc Input, 1.5 Vdc Output 3.3 Vdc Input, 1.2 Vdc Output Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com 1.0 Vdc - 3.3 Vdc/12 A Output 5 Vdc Input 2.5 Vdc Output 5 Vdc Input 1 ...
Page 9
... Vdc Input 3.3 Vdc Output 50% to 100% load 5.0 Vdc Input 2.5 Vdc Output Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com 1.0 Vdc - 3.3 Vdc/12 A Output 5 Vdc Input 1 ...
Page 10
... Vdc Input 1.5 Vdc Output 50% to 100% load 5 Vdc Input 1.5 Vdc Output Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com 1.0 Vdc - 3.3 Vdc/12 A Output 100% to 50% load 3.3 Vdc Input 1.8 Vdc Output 100% to 50% load 5 Vdc Input 1 ...
Page 11
... Vdc Input 1.0 Vdc Output Note: Transient response at di/dt=0.5 A/uS, with external load capacitance = 330 uF, Ta=25 deg C. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com 1.0 Vdc - 3.3 Vdc/12 A Output 100% to 50% load 3 ...
Page 12
... NON-ISOLATED DC/DC CONVERTERS 3.0 Vdc - 5.5 Vdc Input Mechanical Outline SRAH-12Fxx0 VRAH-12Fxx0 bel RoHS Compliance Complies with the European Directive 2002/95/EC, calling for the elimination of lead and other hazardous substances from electronic products. These parts are not however compatible with the higher temperatures associated with lead free solder processes and must be soldered using a reflow profile with a peak temperature of no more than 240 º ...