ZPSA20-5 TDK Corporation, ZPSA20-5 Datasheet - Page 13

POWER SUPPLY 5V 4.4A SGL OUTPUT

ZPSA20-5

Manufacturer Part Number
ZPSA20-5
Description
POWER SUPPLY 5V 4.4A SGL OUTPUT
Manufacturer
TDK Corporation
Series
ZPSA20r
Type
Commercialr
Datasheets

Specifications of ZPSA20-5

Voltage - Output
5V
Number Of Outputs
1
Power (watts)
20W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 4.4A
Size / Dimension
3.5" L x 2" W x 0.79" H (88.9mm x 50.8mm x 20mm)
Power (watts) - Rated
20W
Operating Temperature
0°C ~ 70°C
Efficiency
82%
Approvals
CE, CSA, cUL, EN, UL
Line Regulation
±0.5%
Load Regulation
±1%
Brand/series
ZPSA20 Series
Configuration
Open-Frame
Operation
Switching
Output
5 VDC @ 4.4 A
Power, Output
22 W
Primary Type
AC-DC
Special Features
Low Profile, Industry Standard Footprint
Voltage, Input
85 to 264/120 to 370 VAC/VDC
Voltage, Output
5 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1745
ZPSA205

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ZPSA20-5
Manufacturer:
TDK-LAMBD
Quantity:
617
Product HANDBOOK
ZPSA20 Series
Special Safety Instructions:
Standard Specific Safety Instructions:
Whilst all individual outputs are classed as SELV outputs in accordance with the standard
IEC/EN/UL/CSA60950-1 (<60Vdc or 42.4V peak), seriesed combinations of these outputs may exceed these
values and become hazardous output voltages.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
Environmental Specifications:
Description
Operation
Storage
Use
Indoor
-
0° C - +70° C (derating at 2.5%/°C from 50° C)
Temperature
(For ZPSA40/60 -3,-5,-9)
-20° C - +85° C
0° C - +70° C derating at 2.5%/° C from 40° C)
Humidity
10 - 95% RH, non-condensing
10 - 95% RH, non-
condensing
Altitude
2000M
2000M
Orientation
See Fig 1
ALL
Material Group
IIIb
Pollution Degree
2
IP Protection Class
IPX0
Level of Insulation:
Dielectric Strength testing is carried out as follows:
Primary mains to earth: 1.5kVAC
Primary mains circuits to secondary: 3kVAC, 4142VDC
Output to earth isolation 500VDC
.Safety Approvals:
nd
UL/cUL60950-1 (2
Edition)
nd
IEC / EN60950-1(2
Edition)
CE marking when applied to any ZPSAxx-yy product indicates compliance with the Low Voltage Directive
nd
(2006/95/EC) in that it complies with EN60950-1 (2
Edition).
Fusing: Internal fuses (F1): Single fuse in the L line, T2.2AL, 250V,
Input Connection
ACN – Neutral ACL – Live
Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal
ZPSA20 –xx

Related parts for ZPSA20-5