LS50-12 TDK Corporation, LS50-12 Datasheet

POWER SUPPLY 12V 4.2A SGL OUTPUT

LS50-12

Manufacturer Part Number
LS50-12
Description
POWER SUPPLY 12V 4.2A SGL OUTPUT
Manufacturer
TDK Corporation
Series
LSr
Type
Industrialr
Datasheets

Specifications of LS50-12

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
50W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
88 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 4.2A
Size / Dimension
3.9" L x 3.8" W x 1.4" H (99.1mm x 96.5mm x 35.6mm)
Power (watts) - Rated
50.4W
Operating Temperature
-25°C ~ 70°C
Efficiency
84%
Approvals
CE, EN, IEC, UL
Brand/series
LS Series
Configuration
Enclosed
Current, Output
4.2
Frequency, Input
47-63 Hz
Height
1.4 Inch
Length
3.9 Inch
Line Regulation
48 mV
Load Regulation
96 mV
Operation
Switching
Output
12 VDC @ 4.2 A
Power Rating
50 Watts
Power, Output
50.4 W
Primary Type
AC-DC
Ripple, Rejection
120 mV
Temperature, Operating
–25 to 70 degree C
Temperature, Storage
–40 to 85 degree C
Voltage, Adjustment Range
10.80-13.20
Voltage, Input
88 to 264/125 to 373 VAC/VDC
Voltage, Output
12 VDC
Weight
12.5 Ozs.
Width
3.8 Inch
Output Current (max)
4.2A
Output Voltage
12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-25C
Operating Temperature Max Deg. C
70C
Mounting Style
Chassis
Pin Count
5
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1818
LS5012
* Read instruction manual carefully , before using the power supply unit.
* 1 : At Maximum Output Power, nominal input voltage, Ta = 25°C.
* 2 : For cases where conformance to various safety specs ( UL, CSA, EN ) are required, to be described as 100 - 240VAC, 50 / 60Hz on name plate.
* 3 : Not applicable for the in-rush current to Noise Filter for less than 0.2mS.
* 4 : Ripple & noise are measured at 20MHz by using a 300mm twisted pair of load wires terminated with a 0.1uF film capacitor and a 47uF electrolytic capacitor.
* 5 : Measure line & load regulation at output terminal M3.5 tapped point.
* 6 : 88 - 264VAC, constant load.
* 7 : No load - Full load (Maximum power ), constant input voltage.
* 8 : Current limit with automatic recovery.Avoid to operate at overload or dead short for more than 30 seconds.
* 9 : OVP circuit will shutdown output, manual reset (Re-power on).
* 10: Measured by each measuring method of UL and EN (at 60Hz), Ta = 25°C.
* 11: Refer to Output Derating Curve (PA582-01-02_) for details of output derating versus ambient temperature.
* 12: All parameters NOT specifically mentioned are measured at 230VAC input, rated load and Ta = 25
10 Ripple and Noise
11 Line Regulation
12 Load Regulation
13 Temperature Coefficient
14 Over Current Protection
15 Over Voltage Protection
16 Hold-Up Time (Typ)
17 Leakage current
18 Series Operation
19 Operating Temperature
20 Operating Humidity
21 Storage Temperature
22 Storage Humidity
23 Cooling
24 Withstand Voltage
25 Isolation Resistance
26 Vibration
27 Shock (In package)
28 Safety
29 EMI
30 Immunity
31 Weight (Typ)
32 Dimension (L x W x H)
1
2
3
4
5
6
7
8
9
Nominal Output Voltage
Maximum Output Current
Maximum Output Power
Efficiency (Typ)
Input Voltage Range
Input Current (Typ)
Inrush Current (Typ)
Harmonic Current
Output Voltage Range
PA582-01-01
ITEMS
LS50
= NOTES=
(115/230VAC)
(115/230VAC)
(230VAC)
MODEL
( * 5, 6 ) mV
( * 5, 7 ) mV
( * 1, 4 ) mV
( * 10 )
( * 11 )
( * 1 )
( * 2 )
( * 1 )
( * 3 )
( * 8 )
( * 9 )
( * 1 ) mS
mm
W
%
V
A
A
V
A
V
g
SPECIFICATIONS
Input - FG, Input - Output and Output - FG: More than 100MΩ (500VDC) at 25
3.8 ~ 4.45
LS50-3.3
3 ~ 3.6
3.3
10
33
75
80
20
40
88 ~ 264VAC (47-63Hz) or 125 ~ 373VDC (Withstand 300VAC Surge for 5 seconds)
5.75 ~ 6.75
4.75 ~ 5.5
Input - Output : 3.0kVAC (20mA), Input - FG : 1.5kVAC (20mA)
Built to meet EN61000-4-2 (Level 2,3), -3 (Level 3), -4 (Level 3),
LS50-5
10
50
80
80
20
40
5
Approved by UL60950-1, EN60950-1, IEC60950-1
- 25 ~ + 70 °C (Refer to Output Derating Curve)
Built to meet EN55011/EN55022-B, FCC-B
At no operating, 10 - 55Hz (sweep for 1min)
Output - FG : 500VAC (100mA) for 1min.
-5 (Level 4), -6 (Level 3), -8 (Level 4), -11
99 x 97 x 36 (Refer to Outline Drawing)
40A at 230VAC, Ta=25°C (Cold Start)
10.8 ~ 13.2
13.8 ~ 16.2 17.25 ~ 20.25 27.6 ~ 32.4
19.6m/s
LS50-12
50.4
120
4.2
Built to meet IEC61000-3-2, -3
12
84
48
96
20 ~ 90%RH (No dewdrop)
10 ~ 95%RH (No dewdrop)
> 110% rated output power
o
2
C.
Constant, X, Y, Z 1hour each.
Less than 196.1m/s
Less than 0.02%/°C
Convection cooling
< 1mA at 230VAC
- 40 ~ +85°C
13.5 ~ 16.5
LS50-15
1.3 / 0.8
Possible
14 / 60
120
120
350
3.4
15
51
85
60
2
22 ~ 27.2
LS50-24
52.8
120
192
2.2
24
86
96
DENSEI-LAMBDA
41.4 ~ 48.6
LS50-36
32 ~ 40
50.4
150
144
288
1.4
36
86
o
C and 70%RH
55.2 ~ 64.8
LS50-48
42 ~ 54
52.8
200
192
384
1.1
48
86

Related parts for LS50-12

LS50-12 Summary of contents

Page 1

... OVP circuit will shutdown output, manual reset (Re-power on). * 10: Measured by each measuring method of UL and EN (at 60Hz 25°C. * 11: Refer to Output Derating Curve (PA582-01-02_) for details of output derating versus ambient temperature. * 12: All parameters NOT specifically mentioned are measured at 230VAC input, rated load and SPECIFICATIONS MODEL LS50-3.3 LS50-5 LS50- ...

Page 2

... LS50 PA582-01-02 *COOLING : CONVECTION COOLING -25 ~ +50 70 OUTPUT DERATING CURVE 120 100 -25 0 OUTPUT DERATING LOAD (%) STANDARD MOUNTING 100 (˚C) DENSEI-LAMBDA TB1 75 100 ...

Related keywords