HWS300-24 TDK Corporation, HWS300-24 Datasheet

PWR SUP IND 24V 14A SNG OUTPUT

HWS300-24

Manufacturer Part Number
HWS300-24
Description
PWR SUP IND 24V 14A SNG OUTPUT
Manufacturer
TDK Corporation
Series
HWSr
Type
Industrialr
Datasheets

Specifications of HWS300-24

Power Supply Type
Switching (Closed Frame)
Voltage - Output
24V
Number Of Outputs
1
Power (watts)
300W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 14A
Size / Dimension
6.5" L x 2.4" W x 3.23" H (165.1mm x 61mm x 82mm)
Power (watts) - Rated
336W
Operating Temperature
-10°C ~ 71°C
Efficiency
85%
Approvals
CE, CSA, IEC, EN, UL
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
14A
Power Rating
336W
Input Voltage
85V AC To 265V AC / 120V DC To 330V DC
Brand/series
HWS Series
Configuration
Enclosed
Current, Rating
14.00 A (Max.)
Operation
Switching
Output
24 VDC @ 14 to 16.5 A
Power, Output
336 W
Primary Type
AC-DC
Special Features
Parallelable, PFC, Remote On/Off, Remote Sense
Voltage, Input
85 to 265/120 to 330 VAC/VDC
Voltage, Output
24 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1322
HWS30024

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HWS300-24
Quantity:
35
Part Number:
HWS300-24/A
Manufacturer:
TDK-LAMBDA
Quantity:
158
Part Number:
HWS300-24/HD
Quantity:
77
Part Number:
HWS300-24/ME
Quantity:
123
Features and Benefits
Feature
Specifications
ITEMS
Input Voltage range (47-63Hz)
Input Current (Typ)
Inrush Current
Power Factor
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ)
Leakage Curr. (at 240VAC, 60Hz)
Remote Sense
Indicator
Remote on/off
Parallel operation
DC Good
Remote Adjust (PV)
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Certifications (5)
Line Dip
Conducted & Radiated EMI
Recommended EMI Filter
Immunity
Weight (Typ)
Size (WxHxD)
Warranty
(1) 100/200VAC
(2) HWS start up -20°C. (-40°C see options table)
(3) HWS1000/1500 with 85VAC input: See installation manual
HWS1000: -10 to +71°C. HWS1000-5, HWS1500-3, -5 derate linearly above 40°C
Limited Lifetime Warranty
High Efficiency
Wide Range AC Input
MODEL
(1)
(1)
(4)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
mA
ms
yrs
°C
In
A
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Input to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
2.4 x 3.23 x 6.5"
12-48V: 4.2/2.1
EN55011 / EN55022, FCC VCCI (HWS300, 600 & 1000: Class B, HWS1500: Class A)
5V: 3.8/1.9;
HWS300
MC1206
1,000
HWS300-1500
-10°C to +70°C, derate linearly to 50% load from 50C to 70C (2, 3)
UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark
>105% (>101% of peak current for peak current capable models)
Limited lifetime warranty (See TDK-Lambda's terms and conditions)
10 - 55Hz (1 minute sweep), 19.6m/s
Single Output Industrial Power Supplies
See table on page 2 (Recycle AC or remote on/off to reset)
<0.75mA
IEC61000-4-2, -3, -4, -6 (Level 3), -5, -8 (Level 4), -11
>100M at 25C & 70%RH, Output to Ground 500VDC
85 - 265VAC or 120 - 330VDC
Operating: 10 - 90%RH, Non operating 10 - 95%RH
External voltage adjusts output, see options table
Complies with SEMI F47 (200VAC line only)
3.94 x 3.23 x 6.5"
Benefit
12-48V: 8.1/3.9
Factory Automation
Test & Measurement
Automated Service
Single wire connection (up to 5 units)
Key Market Segments & Applications
Lower Cost of Ownership
Easier System Cooling
Supports Global Use
5V: 7.5/3.6;
(4) 2kVAC HWS1000/1500 Input to ground
(5) UL60601-1, EN60601-1, see options.
(*) Class 1 Div 2 option (/RY suffix)
HWS600
MC1210
Limited Lifetime Warranty
UL508 approved
SEMI F47 Compliant (high line AC)
Universal Input (85 - 265VAC)
High Efficiency
Class 1 Div 2 option (/RY suffix)
1,600
UL508; HWS300/600 5V, 12V, 24V & 48V models
Yes (Isolated from output)
Meets EN61000-3-2
Green LED = ON
-30 to +85°C
< 196.1 m/s
Internal fan
<0.02%/°C
20 / 40
Yes
Yes
20
5-60V: 13.5/7.0
5 x 3.25 x 9.45"
3.3V: 9.6/5.0;
2
2
HWS1000
MC1220
<1.2mA
constant X, Y, Z 1 hour
3,200
3.3-7.5V : 4000; 12V+: 3800
5-60V: 19.5/10.0
3.3V: 15.0/8.0;
5 x 3.25 x 11"
85 - 265VAC
HWS1500
MC1230
<1.5mA
45

Related parts for HWS300-24

HWS300-24 Summary of contents

Page 1

... Output to Ground 500VDC 10 - 55Hz (1 minute sweep), 19.6m/s < 196.1 m/s UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark Complies with SEMI F47 (200VAC line only) EN55011 / EN55022, FCC VCCI (HWS300, 600 & 1000: Class B, HWS1500: Class A) MC1206 MC1210 IEC61000-4-2, -3, -4, -6 (Level 3), -5, -8 (Level 4), -11 1,000 1,600 2.4 x 3.23 x 6.5" ...

Page 2

... HWS1000-12 12V 9.6 - 14.4 HWS1500-12 12V 9.6 - 14.4 HWS300-15 15V HWS600-15 15V HWS1000-15 15V HWS1500-15 15V HWS300-24 24V 19.2 - 28.8 HWS600-24 24V 19.2 - 28.8 HWS1000-24 24V 19.2 - 28.8 HWS1500-24 24V 19.2 - 28.8 HWS1000-36 36V 28.8 - 43.2 HWS1500-36 36V 28.8 - 43.2 HWS300-48 48V 38 ...