LZSA-1000-3 TDK Corporation, LZSA-1000-3 Datasheet - Page 8

PWR SUP 24V 1008W 42A

LZSA-1000-3

Manufacturer Part Number
LZSA-1000-3
Description
PWR SUP 24V 1008W 42A
Manufacturer
TDK Corporation
Series
LZSAr
Type
Industrialr
Datasheets

Specifications of LZSA-1000-3

Power Supply Type
Switching (Closed Frame)
Voltage - Output
24V
Number Of Outputs
1
Power (watts)
1000W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 42 A
Size / Dimension
10.5" L x 5.62" W x 4.75" H (266.7mm x 142.7mm x 120.7mm)
Power (watts) - Rated
1008W
Operating Temperature
-40°C ~ 71°C
Efficiency
84%
Approvals
CE, EN, UL
Line Regulation
0.1%
Load Regulation
0.1%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
42A
Power Rating
1008W
Input Voltage
85V AC To 265V AC / 100V DC To 400V DC
Brand/series
LZSA Series
Configuration
Enclosed
Operation
Linear
Output
24 VDC @ 42 A
Power, Output
1008 W
Primary Type
AC-DC
Special Features
High Reliability, Parallelable, Remote Adjust, Remote On/Off, Remote Sense
Voltage, Input
85 to 265/100 to 400 VAC/VDC
Voltage, Output
24 VDC
Input Frequency
47 to 440Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-40C
Operating Temperature Max Deg. C
71C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1455
LZSA10003

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LZSA-1000-3
Manufacturer:
TDK
Quantity:
100
LZS-A A 1000-3 3 Power Supply
Page. 6
Revision H : December 2009
* See “Overtemperature and Overvoltage Shutdown” on page 7
Protection Features
Mechanical Features
Input and Output Connections
Other Features
Output Voltage Range
Nominal Factory Set Point
Overvoltage Protection (adjustable)
Overcurrent Protection
Thermal Protection
Fusing
Isolation Voltages
Regulatory Agency Compliance
Leakage current (AC line to
chassis ground)
Storage Temperature (non-operating)
Weight
Size
Finish
Mounting
Input
Chassis Ground
DC Output
Local/Remote voltage sensing, Four-position lugless connector (TB201), see Fig. 1.
Remote on/off, Parallel operation. (Accepts up to #14 AWG size stripped wire).
Auxiliary Control and Alarm Signals Connections for remote and local sensing, remote on/off, parallel operation
Warranty
Cooling
Fungus Inert
Humidity
Altitude
Heavy duty terminal block
Tapped hole and screw provided in chassis.
Heavy-duty bus bars with 1/4” clearance holes for load connections.
(Connection hardware supplied with unit.)
current sharing, input power good signal, OV alarm, UV alarm, inverter
good signal and chassis are available via chassis mounted, 15-pin,
female, sub-miniature “D” connector (see Fig. 1).
5 years
Variable speed, Ball Bearing Fan
All LZS power supplies are inherently fungus inert.
10%-90% Non-condensing
0-10,000 Ft (Operating); 40,000 Ft (Non-Operating)
inches
Units
lbs
µA
°C
V
V
V
-
-
-
-
-
-
-
4242 VDC, Input to Output
2121 VDC, Input to Chassis Ground
500 VDC, Output to Chassis Ground
UL 60950-1/CAN CSA C22.2 No. 60950-1-03, First Edition
UL 508, Seventeenth Edition
EN 60950-1:2001+A11, IEC 60950-1:2001,
IEC61000 2nd Edition
FM 3600, FM 3611, FM 3810, Semi F47
Less than 500 µA @ 265 VAC, 60 Hz
-40°C - +85°C
8.1 lb net
5.62” x 4.75” x 10.5”
Textured gray - painted
One mounting surface (mounting position not restricted)
Maximum allowable penetration into power supply is
1/4”. Requires No. M4 (metric) hardware - supplied
with unit.)
Factory set to 110% min. and 130% max.
20-34V (Factory set to 31.0V)
Self-resetting thermostat.*
18-29.4V
Internal
24V
Table 10
Table 12
Table 11
Table 9

Related parts for LZSA-1000-3