2866747 Phoenix Contact, 2866747 Datasheet - Page 2

POWER SUPPLY 3.5A 85-264AC 24DC

2866747

Manufacturer Part Number
2866747
Description
POWER SUPPLY 3.5A 85-264AC 24DC
Manufacturer
Phoenix Contact
Series
Quintr
Type
Industrialr
Datasheets

Specifications of 2866747

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
84W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 3.5A
Size / Dimension
4.92" L x 1.26" W x 5.12" H (125mm x 32mm x 130mm)
Power (watts) - Rated
84W
Operating Temperature
-25°C ~ 70°C
Efficiency
88%
Approvals
ABS, BV, CB, CSA, cUL, GL, LR, NK, UL
Product
Switching
Commercial/medical
Commercial
Output Power Rating
84 W
Input Voltage
100 VAC to 240 VAC
Output Voltage (channel 1)
24 VDC
Output Current (channel 1)
3.5 A
Mounting Style
DIN Rail
Brand/series
QUINT-PS
Configuration
Enclosed
Operation
Switching
Output
24 VDC @ 3.5 A
Phoenix Part Number
QUINT-PS/1AC/24DC/3,5
Power, Output
11 W
Primary Type
AC-DC
Voltage, Input
85 - 264/90 - 350 VAC/VDC
Voltage, Output
24 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
277-1992
QUINT-PS/ 1AC/24DC/ 3.5
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2866747
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Technical data
Input data
Nominal input voltage
AC input voltage range
DC input voltage range
Short-term input voltage
AC frequency range
DC frequency range
Current consumption
Inrush surge current
Power failure bypass
Input fuse
Permissible backup fuse
Additional text
Type of protection
Protective circuit/component
Output data
Nominal output voltage
Setting range of the output voltage
Output current
Derating
Connection in parallel
Connection in series
Control deviation
Residual ripple
Order No.: 2866747
100 V AC ... 240 V AC
85 V AC ... 264 V AC
90 V DC ... 350 V DC
300 V AC
45 Hz ... 65 Hz
0 Hz
Approx. 1.4 A (120 V AC)
Approx. 0.8 A (230 V AC)
< 20 A (typical)
> 20 ms (120 V AC)
> 80 ms (230 V AC)
5 A (slow-blow, internal)
B6
B10
B16
AC: 1 x circuit breaker - recommended fuse
Transient surge protection
Varistor
24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)
3.5 A (-25°C ... 60°C, U
4 A (with POWER BOOST, -25°C ... 40°C permanently, U
V DC)
15 A (SFB technology, 12 ms)
4 A (U
60 °C ... 70 °C (2.5%/K)
Yes, for redundancy and increased capacity
Yes
< 1 % (change in load, static 10% ... 90%)
< 2 % (change in load, dynamic 10% ... 90%)
< 0.1 % (change in input voltage ±10%)
< 50 mV
In
≥ 100 V AC)
PP
(with nominal values)
OUT
= 24 V DC)
Jun 12, 2011