S8VS-01512 Omron, S8VS-01512 Datasheet - Page 23

POWER SUPPLY SW 12VDC 1.2A 15W

S8VS-01512

Manufacturer Part Number
S8VS-01512
Description
POWER SUPPLY SW 12VDC 1.2A 15W
Manufacturer
Omron
Series
S8VSr
Datasheets

Specifications of S8VS-01512

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
15W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
12 VDC @ 1.2A
Size / Dimension
3.79" L x 0.89" W x 3.35" H (96.4mm x 22.5mm x 85mm)
Power (watts) - Rated
15W
Operating Temperature
-10°C ~ 60°C
Efficiency
74%
Approvals
CE, CSA, cUL, EN, UL, VDE
Product
Switching
Output Power Rating
14 W
Output Voltage (channel 1)
12 V
Output Current (channel 1)
1.2 A
Dimensions
96.4 mm L x 22.5 mm W x 85 mm H
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8VS01512
Z2290
Models with Total Run Time Monitor
(S8VS-@@@24B@@/S8VS-@@@24BE@)
S8VS-06024B
The accumulated value of the operating time of the Power Supply is
displayed as the total run time.
purchase and then the display will advance in 1-kh steps as the
operating time accumulates. The S8VS-06024B, however, does not
have an alarm function (setting, display, or output).
S8VS-09024B@@/S8VS-09024BE@/
S8VS-12024B@/S8VS-12024BE/
S8VS-18024B@/S8VS-18024BE/
S8VS-24024B@/S8VS-24024BE/S8VS-48024B
The display will appear when the set value for the total run time has
been reached.
The accumulated value of the operating time of the Power Supply is
displayed as the total run time.
purchase and then the display will advance in 1-kh steps as the
operating time accumulates. When the total run time reaches the
alarm set value, the alarm (
displayed alternately and a transistor (total run time output terminal
(kh)) will output the status externally.
(Alarm set value reached = OFF, i.e., no continuity at the total run time
output terminal (kh))
The alarm set value can be changed in the setting mode.
The S8VS-09024BE@, S8VS-12024BE, S8VS-18024BE, and S8VS-
24024BE do not have an alarm output.
Example: Alarm Displays When a Total Run Time Set Value of
88 kh Is Reached
Note: The total run time cannot be reset. To clear the alarm, change
Operation mode
Total run time
Output
voltage
Output
current
Peak hold
current
the alarm set value to a value higher than the value displayed
for the total run time.
Total run time set value reached.
a02
0
0
) and the total run time will be
(kh) will be displayed initially after
(kh) will be displayed initially after
(See note.)
Note: The alarm (a02)
Total run time
and the total run
time will be
displayed
alternately.
Time Chart
* Setting is possible for the following models only:
Note: 1. The total run time does not include the time that the Power
Alarm output
Set value = 50 kh
(See note.)
Total run time
S8VS-09024B@@, S8VS-09024BE@, S8VS-12024B@,
S8VS-12024BE, S8VS-18024B@, S8VS-18024BE,
S8VS-24024B@, S8VS-24024BE, S8VS-48024B
2. The total run time measures the total time that power is
AC input
Supply is OFF.
being supplied and is not related in any way to deterioration
in the electrolytic capacitor built into the Power Supply or to
the effects of the ambient temperature.
50 kh
0 kh
S8VS
23

Related parts for S8VS-01512