S82K-00724 Omron, S82K-00724 Datasheet - Page 13

POWER SUPPLY 24V .3A DIN RAIL

S82K-00724

Manufacturer Part Number
S82K-00724
Description
POWER SUPPLY 24V .3A DIN RAIL
Manufacturer
Omron
Series
S82Kr
Datasheet

Specifications of S82K-00724

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
7W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 300mA
Size / Dimension
2.56" L x 1.48" W x 2.95" H (65mm x 37.5mm x 75mm)
Power (watts) - Rated
7.5W
Operating Temperature
-10°C ~ 50°C
Efficiency
64%
Approvals
CE, CSA, cUL, cUR, UL, VDE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
S82K00724
Z1182
Safety Precautions
Refer to Safety Precautions for All Power Supplies.
■ Precautions for Safe Use
Mounting
Take adequate measures to ensure proper heat dissipation to
increase the long-term reliability of the product.
The Power Supply is designed to radiate heat by means of natural
air-flow. Therefore, mount the Power Supply so that air flow takes
place around the Power Supply.
When mounting two or more Power Supplies side-by-side, allow at
least 10 mm spacing between them, as shown in the following
illustration.
Forced air-cooling is recommended.
To mount the Power Supply on a DIN rail, hook portion (A) of the
Power Supply to the rail and press the Power Supply toward direction
(B).
Minor electric shock, fire, or Product failure may
occasionally occur. Do not disassemble, modify, or repair
the Product or touch the interior of the Product.
Minor burns may occasionally occur. Do not touch the
Product while power is being supplied or immediately
after power is turned OFF.
Fire may occasionally occur. Tighten terminal screws to
the specified torque of 0.98 N·m (M3.5).
Minor injury due to electric shock may occasionally occur.
Do not touch the terminals while power is being supplied.
Always close the terminal cover after wiring.
Minor electric shock, fire, or Product failure may
occasionally occur. Do not allow any pieces of metal or
conductors or any clippings or cuttings resulting from
installation work to enter the Product.
10 mm min.
!CAUTION
(B)
Air
(A)
Short bar
To dismount the Power Supply, pull down portion (C) with a flat-blade
screwdriver and pull out the Power Supply.
Wiring
Do not apply more than 75-N force to the terminal block when
tightening it.
Ensure that input and output terminals are wired correctly.
Selection of 100 or 200 VAC Input
Voltage
(S82K-@09024/-@10024)
Select a 100-V or 200-V input by shorting or opening the input volt-
age selector terminals, as shown in the following diagram.
(The default setting is 200 V.)
Generating Output Voltage (±)
An output of ± can be generated by using two Power Supplies as
shown below, because the Power Supply produces a floating output.
Correct
When connecting the Power Supplies in series with an operation
amplifier, connect diodes to the output terminals as shown by the
dotted lines in the figure. No diodes are required with S82K-@09024
and S82K-@10024.
100-V Input
200-V Input
Use the short bar to short-circuit
terminals 7 and 8.
INPUT
INPUT
Remove the short bar to
open terminals 7 and 8.
(C)
+V
−V
+V
−V
Rail stopper
30 mm min.
S82K
13