S8VS-18024 Omron, S8VS-18024 Datasheet - Page 25

POWER SUPPLY SW 24VDC 7.5A 180W

S8VS-18024

Manufacturer Part Number
S8VS-18024
Description
POWER SUPPLY SW 24VDC 7.5A 180W
Manufacturer
Omron
Series
S8VSr
Datasheets

Specifications of S8VS-18024

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
180W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 7.5A
Size / Dimension
4.93" L x 2.95" W x 4.53" H (125.3mm x 75mm x 115mm)
Power (watts) - Rated
180W
Operating Temperature
-10°C ~ 60°C
Efficiency
80%
Approvals
CE, CSA, cUL, EN, UL, VDE
Product
Switching
Output Power Rating
180 W
Input Voltage
100 VAC to 240 VAC
Output Voltage (channel 1)
24 V
Output Current (channel 1)
7.5 A
Mounting Style
DIN Rail
Dimensions
125.3 mm L x 75 mm W x 115 mm H
Open Frame/enclosed
Enclosed
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8VS18024
Z2298
Undervoltage Alarm Function (Indication and
Output) (S8VS-@@@24A@@/S8VS-@@@24B@@/
S8VS-@@@24BE@ Only)
When output voltage drop is detected, an alarm (
output voltage value are indicated alternately. The preset value of
detection voltage can be changed in the setting mode.
(From 18.5 to 27.5 V in 0.1-V steps. The value is fixed at 20.0 V for
the S8VS-06024A/S8VS-06024B.)
Further, an output (undervoltage output terminal (DC LOW)) to an
external device is given from the transistor to notify of the error
(excluding S8VS-06024A/S8VS-06024B/S8VS-@@@24BE@).
(Output voltage drop = OFF, i.e., no continuity at the undervoltage
output terminal (DC LOW).)
Example: Outputting an Alarm When the Voltage Output by the
S8VS-09024A@@ Drops to the Set Value (19.0 V) or Lower
Note: 1. Operation begins after about three seconds since the AC
Note: Operation begins after about three seconds since the AC
AC input
Output
voltage
Undervoltage
output
Main display
2. The alarm is not indicated in the setting mode.
3. Press the
4. The undervoltage alarm function may also operate when an
5. The undervoltage alarm function monitors the output
power is supplied.
power is supplied.
restored, to reset alarm indication.
interruption in AC input is not restored within 20 ms.
terminal voltage of the Power Supply. To check the voltage
accurately, measure the voltage at the load end.
Operation
mode
(Mode Key (8)) after the output voltage is
Lowest value of
output voltage
In the case that the
output voltage drops
below the set value (19.0 V)
and an alarm is issued
a01
Voltage indication
) and lowest
Detection value
of Undervoltage
alarm
:
S8VS
25

Related parts for S8VS-18024