ZPSA20-15 TDK Corporation, ZPSA20-15 Datasheet - Page 14

POWER SUPPLY 15V 1.4A SGL OUTPUT

ZPSA20-15

Manufacturer Part Number
ZPSA20-15
Description
POWER SUPPLY 15V 1.4A SGL OUTPUT
Manufacturer
TDK Corporation
Series
ZPSA20r
Type
Commercialr
Datasheets

Specifications of ZPSA20-15

Number Of Outputs
1
Efficiency
82%
Voltage - Output
15V
Power (watts)
20W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
15 VDC @ 1.4A
Size / Dimension
3.5" L x 2" W x 0.79" H (88.9mm x 50.8mm x 20mm)
Power (watts) - Rated
20W
Operating Temperature
0°C ~ 70°C
Approvals
CE, CSA, cUL, EN, UL
Line Regulation
±0.5%
Load Regulation
±1%
Input Voltage
85 to 264V
Output Voltage
15V
Output Power (max)
20W
Input Frequency
47 to 440Hz
Screening Level
Commercial
Product Depth (mm)
50.8mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Screw
Pin Count
8
Brand/series
ZPSA20 Series
Configuration
Open-Frame
Operation
Switching
Output
15 VDC @ 1.4 A
Power, Output
21 W
Primary Type
AC-DC
Special Features
Low Profile, Industry Standard Footprint
Voltage, Input
85 to 264/120 to 370 VAC/VDC
Voltage, Output
15 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1748
ZPSA2015

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ZPSA20-15
Manufacturer:
TDK-LAMBDA
Quantity:
617
Input Parameters:
Output Parameters:
Output connector mates with Molex housing 09-50-3041 and Molex 2878 series crimp terminal
Adjusting output voltage beyond the set value stated may cause overvoltage protection (OVP) to operate,
whereby the output will latch
output voltage to within its range and cycle the input off then on.
All outputs are SELV except under the following circumstance: Outputs connected in series are non-SELV if
the total output voltage exceeds 60Vdc
If the total voltage of outputs connected in series exceed the 60Vdc SELV limit then all outputs must be
considered non-SELV.
Non-SELV outputs are hazardous and must not be made user accessible. Consideration must be given to
service engineers making inadvertent contact with the output terminals in the end equipment.
Cooling for unit
The ZPSA20 series are convection cooled, recommended installation
Equipment top
Standard
Rated input voltage
Input voltage range
Input frequency range
Maximum input current
115/240VAC
Inrush current
Class of Equipment
Overvoltage Category
Product HANDBOOK
Model
20W
Vout (V)
3.3
12
15
24
off.
5
9
To reset for normal operation simply adjust the potentiometer to reduce the
130mA/
0.70mA
current (A)
Output
ZPSA20 Series
4.4
4.4
2.4
1.8
1.4
0.9
30A max at 230VAC
100-240 VAC
90 – 264VAC
47 – 63Hz
0.130mA
60950-1
270mA/
II
II
0.200mA
400mA/