ZPSA6048 TDK Corporation, ZPSA6048 Datasheet - Page 13

POWER SUPPLIES AC-DC 48V 1.25A

ZPSA6048

Manufacturer Part Number
ZPSA6048
Description
POWER SUPPLIES AC-DC 48V 1.25A
Manufacturer
TDK Corporation
Series
ZPSA60r
Datasheets

Specifications of ZPSA6048

Power Supply Type
Switching (Open Frame)
Voltage - Output
48V
Number Of Outputs
1
Power (watts)
60W
Applications
Commercial
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 1.25A
Size / Dimension
4" L x 2" W x 1.07" H (101.6mm x 50.8mm x 27.1mm)
Power (watts) - Rated
60W
Operating Temperature
0°C ~ 70°C
Efficiency
88%
Approvals
CE, CSA, EN, UL
Line Regulation
±0.5%
Load Regulation
±1%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
48V
Output Current
1.25A
Power Rating
60W
Input Voltage
90V AC To 264V AC / 120V DC To 370V DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
285-1847
Product HANDBOOK
ZPSA40/60 Series
Special Safety Instructions:
Standard Specific Safety Instructions:
Whilst all individual outputs are classed as SELV outputs in accordance with the standard
IEC/EN/UL/CSA60950-1 (<60Vdc or 42.4V peak), seriesed combinations of these outputs may exceed these
values and become hazardous output voltages.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
Environmental Specifications:
Description
Operation
Storage
Use
Indoor
-
0° C - +70° C (derating at 2.5%/°C from 50° C)
Temperature
(For ZPSA40/60 -3,-5,-9)
-20° C - +85° C
0° C - +70° C derating at 2.5%/° C from 40° C)
Humidity
10 - 95% RH, non-condensing
10 - 95% RH, non-
condensing
Altitude
2000M
2000M
Orientation
See Fig 1
ALL
Material Group
IIIb
Pollution Degree
2
IP Protection Class
IPX0
Level of Insulation:
Dielectric Strength testing is carried out as follows:
Primary mains to earth: 1.5kVAC
Primary mains circuits to secondary: 3kVAC, 4142VDC
Output to earth isolation 500VDC
.Safety Approvals:
nd
UL/cUL60950-1 (2
Edition)
nd
IEC / EN60950-1(2
Edition)
CE marking when applied to any ZPSA40/60-xx product indicates compliance with the Low Voltage Directive
nd
(2006/95/EC) in that it complies with EN60950-1 (2
Edition).
Fusing: Internal fuses (F1): Single fuse in the L line, T2.2AL, 250V,
Input Connection
ACN – Neutral ACL – Live
Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal
ZPSA40/60 –xx