SCS120PW48 TDK Corporation, SCS120PW48 Datasheet - Page 98
SCS120PW48
Manufacturer Part Number
SCS120PW48
Description
POWER SUP 48V 2.5A 120W OUTPUT
Manufacturer
TDK Corporation
Series
SCS120PWr
Datasheets
1.SCS120PW48.pdf
(2 pages)
2.SCS120PW48.pdf
(2 pages)
3.SCS120PW48.pdf
(1 pages)
4.SCS120PW48.pdf
(169 pages)
Specifications of SCS120PW48
Voltage - Output
48V
Number Of Outputs
1
Power (watts)
120W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 2.5A
Size / Dimension
5" L x 3" W x 1.27" H (127mm x 76.2mm x 32.3mm)
Power (watts) - Rated
120W
Operating Temperature
0°C ~ 40°C
Efficiency
85%
Approvals
CE, CSA, EN, UL
Line Regulation
±3%
Load Regulation
±3%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
48V
Output Current
2.5A
Power Rating
120W
Input Voltage
90VAC To 264VAC
Supply Voltage Typ
115VAC / 230VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
285-1969
Features and Benefits
Feature
Specifications
ITEMS
Input Voltage range
Inrush Current
Input Current (115/230VAC)
Leakage Current
Hold Up Time (Typ)
Temperature Coefficient
Voltage Accuracy
Adjustment Range
Minimum Load
Load Regulation
Line Regulation
Ripple & Noise (2)
Short Circuit Protection
Overvoltage Protection
Efficiency
LED Indicator
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Certification
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (WxLxH)
Warranty
(1) Safety certified for 47 - 63Hz input only
(2) Measured with 0.1uF ceramic & 10uF electrolytic at 20MHz BW
Industry standard footprint
Wide Range AC Input
Class B conducted EMI
(1)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
mm
mA
mV
ms
yr
A
A
A
%
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ZPSA20 Series
Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
23.52m/s
0 to +70°C derate linearly to 37.5% load from 45 to 70°C
40A maximum at 240VAC input, 25°C ambient cold start
UL60950-1, CSA60950-1 (cUL), EN60950-1, CE Mark
>100M at 25C & 70%RH, Output to Ground 500VDC
2 x 3.5 x 0.79 (including underside components)
85 - 264VAC (47 - 440Hz) or 120 - 370VDC
2
Benefit
Video/Audio Routers
Datacom
Point of Sale
Test and Measurement
(10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
Key Market Segments & Applications
110 - 130% of nominal (Zener clamp)
Availability to second source
Global Operation
Reduced system filtering required
2 x 3.5" 20W AC-DC Power Supplies
±0.5% (100 - 240VAC line change)
Wide Range AC Input
Low profile, Industry Standard Footprint
Global Safety Agency Compliance
0.6mA maximum (264VAC, 60Hz)
1% or 50mV whichever is greater
EN61000-4-2, -3, -4, -5, -6, -8
±1% (10 - 100% load change)
Continuous - hiccup mode
EN55022-B, FCC Class B
8ms at 115VAC input
< 196.1 m/s
Green LED = OK
-20 to +85°C
10 - 95% RH
0.25 / 0.12
±0.05%/°C
82% typical
Convection
One Year
ZPSA20
None
None
100g
±1%
2
(20G)
97