ZWS240PAF36 TDK Corporation, ZWS240PAF36 Datasheet

PWR SUP 36V 241.2W 6.7A

ZWS240PAF36

Manufacturer Part Number
ZWS240PAF36
Description
PWR SUP 36V 241.2W 6.7A
Manufacturer
TDK Corporation
Series
ZWSr
Type
Open Framer
Datasheets

Specifications of ZWS240PAF36

Number Of Outputs
1
Efficiency
82%
Voltage - Output
36V
Power (watts)
240W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
36 VDC @ 6.7A
Size / Dimension
8.74" L x 3.74" W x 1.65" H (222mm x 95mm x 42mm)
Power (watts) - Rated
241.2W
Operating Temperature
-10°C ~ 70°C
Approvals
CE, CSA, EN, UL
Line Regulation
0.4%
Load Regulation
0.8%
Output Current (max)
8.4A
Input Voltage
85 to 265V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
70C
Mounting Style
Chassis
Pin Count
13
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
285-1719
F e a t u r e s a n d B e n e f i t s
Feature
S p e c i f i c a t i o n s
ITEMS
Input Voltage
Input Current (Forced air) (1)
Inrush Current
Power Factor
Leakage Current
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ) at 100VAC
Efficiency
Remote On/Off
Line Regulation
Load Regulation
Ripple & Noise
Operating Temperature
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Recommended EMI Filter
Immunity
Weight (Typ)
Size (WxHxD)
Warranty
Notes:
(1)
(2)
Input Transient Protected
Power Factor Corrected
200% Peak Power capability
100/200VAC
25°C ambient (cold start)
MODELS
(1,2)
(3)
(4)
(4)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
mm
mA
ms
yrs
A
A
%
%
%
%
V
g
-
ZWS-PAF Series
(Open frame or L bracket) -10°C to +70°C, derate linearly to 70% load from 60°C to 70°C
(With /A cover option) -10°C to +60°C, derate linearly to 70% load from 50°C to 60°C
150W to 480W Single Output Power Supplies
500g (800g with cover)
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA),
ZWS150PAF
10 - 55Hz (1 minute sweep), 19.6m/s
UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark
See installation manual (Not available with /A cover option)
0.5mA Max. Typically 0.1mA (100VAC), 0.22mA (230VAC)
2.8/1.4
0.99 at 100VAC, 0.95 at 200VAC, Meets EN61000-3-2
>100M at 25C & 70% RH, Output to Ground 500VDC
Operating: 30 - 90% RH, Operating: 10 - 95% RH
24V: 30-35V, 36V: 43.2-50.4, 48V: 55.2-64.8V
Output to Ground 500VAC (100mA) for 1 min.
EN55022/EN55022-B, FCC Class B, VCCI-B
(3)
(4)
Convection or Forced Air Cooled (1.5m/s)
Benefit
85-265VAC (47-63Hz), 120-370VDC
20 (16ms at forced air power ratings)
Factory Automation
Test & Measurement
Light Industrial Equipment
EN61000-4-2, -3, -4, -5, -6, -8, -11
Avoid prolonged operartion in overload
With 0.7m/s airflow. See derating table for convection cooling
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Withstands harsh environments
Supports Global Use
Can drive high current start up or pulse loads
>102% of peak current capability
Universal Input (85 - 265VAC)
Power factor Corrected
200% Peak Power capability
2 year warranty
Less than 0.5mA earth leakage current
See Outline Drawings
MAW1205-22
-30 to +85°C
< 196.1 m/s
<0.02%/°C
Two Years
14 / 28
0.4%
0.8%
1%
82
2
2
constant X, Y, Z 1 hour
750g (1100g with cover)
ZWS240PAF
4.0/2.0
93

Related parts for ZWS240PAF36

ZWS240PAF36 Summary of contents

Page 1

ZWS-PAF Series Feature Input Transient Protected Power Factor Corrected 200% Peak Power capability ...

Page 2

... ZWS150PAF48 48V 43.2 - 52.8V ZWS240PAF24 24V 21.6 - 28.8V ZWS240PAF36 36V 32.4 - 41.4V ZWS240PAF48 48V 43.2 - 52.8V Note 5: For 10s maximum, 35% duty cycle, average power not to exceed maximum ratings Note 6: With 1.5m/s forced air Model Derating for Conducted Cooling Model 25° ...

Related keywords