SWS60036 TDK Corporation, SWS60036 Datasheet

PWR SUP 36V 16.7A SNG OUTPUT

SWS60036

Manufacturer Part Number
SWS60036
Description
PWR SUP 36V 16.7A SNG OUTPUT
Manufacturer
TDK Corporation
Series
SWSr
Type
Enclosedr
Datasheets

Specifications of SWS60036

Number Of Outputs
1
Efficiency
85%
Voltage - Output
36V
Power (watts)
600W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
36 VDC @ 16.7A
Size / Dimension
7.48" L x 3.62" W x 4.72" H (190mm x 91.9mm x 119.9mm)
Power (watts) - Rated
601.2W
Operating Temperature
-10°C ~ 65°C
Approvals
CE, CSA, EN, UL
Output Current (max)
16.7A
Input Voltage
85 to 265V
Output Power (max)
600W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Height (mm)
120mm
Product Depth (mm)
92mm
Operating Temperature Min Deg. C
-10C
Mounting Style
Desktop
Pin Count
15
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
285-1632
SWS600-36
CA741-01-01C
* Read instruction manual carefully , before using the power supply unit.
* 1 : At maximum output power, nominal input voltage, Ta = 25°C.
* 2 : For cases where conformance to various safety specs ( UL, CSA, EN ) are required, to be described as 100 - 240VAC, 50 / 60Hz on name plate.
* 3 : First inrush current, not applicable for the in-rush current to Noise Filter for less than 0.2ms.
* 4 : Please refer to Fig A for measurement of line & load regulation, ripple and noise voltage.
* 5 : 85 - 265VAC, constant load.
* 6 : No load - Full load(Maximum power), constant input voltage.
* 7 : Constant current limit with automatic recovery.
* 8 : OVP, OTP circuit will shutdown output, manual reset (Re power on).
* 9 : Measured by each measuring method of UL, CSA, EN.
*10: Refer to Output Derating Curve (next page) for details of output derating
*11: Operating period at peak output current is less than 5sec.(Duty<=0.35).
10 PFHC
11 Power Factor (Typ)
12 Output Voltage Range
13 Ripple and Noise
14 Line Regulation
15 Load Regulation
16 Temperature Coefficient
17 Over Current Protection
18 Over Voltage Protection
19 Over Temperature Protection
20 Hold-Up Time (Typ)
21 Leakage current
22 Remote Sensing
23 Remote ON/OFF control
24 Monitoring Signal
25 Parallel Operation
26 Series Operation
27 Operating Temperature
28 Operating Humidity
29 Storage Temperature
30 Storage Humidity
31 Cooling
32 Withstand Voltage
33 Isolation Resistance
34 Vibration
35 Safety
36 EMI
37 Immunity
38 Weight (Typ)
39 Dimension
1
2
3
4
5
6
7
8
9
Nominal Output Voltage
Maximum Output Current
Peak Output Current
Maximum Output Power
Peak Output Power
Efficiency (Typ)
Input Voltage Range
Input Current (Typ)
Inrush Current (Typ)
Ripple & noise are measured at 20MHz by using a 12'' twisted pair terminated with a 0.1uF and 47uF capacitor.
Avoid to operate at overload or dead short for more than 30seconds.
versus input voltage, ambient temperature and mounting method .
(Average output power and current is less than Maximum output power and current)
ITEMS
= NOTES=
(115/230VAC)
(115/230VAC)
(115/230VAC)
(115/230VAC)
(115/230VAC) ( * 1, 4 ) mV
( * 2,10 )
( * 4, 5 ) mV
( * 4, 6 ) mV
( * 10 )
MODEL
( * 1 ) %
( * 1 ) A
( * 3 )
( * 1 )
( * 7 )
( * 8 )
( * 8 )
( * 1 )
( * 9 )
( * 1 )
( * 1 )
(*11)
(*11) W
SWS600 SPECIFICATIONS
mm
W
V
A
A
V
A
V
g
SWS600-3
2.97~3.96
4.3 / 2.2
4.1~5.3
69 / 71
126~
100
120
330
396
100
3.3
20
40
Output - FG : 500VAC (100mA), Output - CNT : 100VAC (100mA) for 1min.
More than 100MΩ at Ta=25°C and 70%RH, Output - FG : 500VDC
SWS600-5
6.25~7.5
Input - Output : 3.0kVAC (20mA), Input - FG : 2.0kVAC (20mA)
6.6 / 3.3
4.5~6.0
Approved by UL60950-1, CSA60950-1, EN60950-1, EN50178
74/77
1.5mA Max, 0.5mA(Typ) at 115VAC / 1mA(Typ) at 230VAC
126~
100
120
500
600
100
20
40
5
Built to meet FCC-Class B, EN55011/EN55022-B
At no operating, 10 - 55Hz ( sweep for 1min )
20A at 115VAC, 40A at 230VAC, Ta=25°C
Built to meet EN61000-4-2,-3,-4,-5,-6,-8,-11
85 ~ 265VAC (47-63Hz) or 120 ~ 370VDC
92 x 120 x 190 (Refer to Outline Drawing)
SWS600-12 SWS600-15
Measurement point for Vo Line/Load
Regulation, and ripple and noise.
13.8~16.8
19.6m/s
9.6~13.2
78 / 81
52.5~
600
120
12
50
48
96
---
---
30 ~ 90 %RH (No dewdrop)
Built to meet EN61000-3-2
PF (Open Collector Output)
10 ~ 95%RH (No dewdrop)
Forced air by blower fan
2
Constant, X, Y, Z 1hour each
Less than 0.02%/°C
TB51
- 10 ~ + 65 °C
13.2~18.6
19.3~24.2
- 30 ~ +85°C
80 / 83
0.99/0.95
Possible
Possible
Possible
Possible
600
120
120
42~
20ms
15
40
48
2000
---
---
Yes
+V
-V
SWS600-24
30.0~34.8
20~28.8
7.2 / 3.6
81/84
26.2~
600
150
120
24
25
48
---
---
Fig. A
SWS600-36
DENSEI-LAMBDA
41.4~50.4
28.8~40
81 / 85
17.6~
601.2
16.7
A
200
180
36
72
---
---
SWS600-48
60.0~69.6
40~57.6
82/85
13.1~
12.5
600
240
240
48
---
---
96

Related parts for SWS60036

SWS60036 Summary of contents

Page 1

CA741-01-01C ITEMS 1 Nominal Output Voltage 2 Maximum Output Current 3 Peak Output Current 4 Maximum Output Power 5 Peak Output Power 6 Efficiency (Typ) (115/230VAC) 7 Input Voltage Range 8 Input Current (Typ) (115/230VAC) 9 Inrush Current (Typ) 10 ...

Page 2

CA741-01-02A SWS600 OUTPUT DERATING VS AMBIENT TEMPERATURE 100 - SWS600 OUTPUT DERATING VS INPUT VOLTAGE 100 115 145 MOUNTING A (STANDARD MOUNTING) SWS600 OUTPUT DERATING 55% 20 ...

Related keywords