POWER SUPPLY 3.3V 120A SGL OTPT

SWS600L-3

Manufacturer Part Number
SWS600L-3
Description
POWER SUPPLY 3.3V 120A SGL OTPT
Manufacturer
TDK Corporation
Series
SWSr
Datasheet

Specifications of SWS600L-3

Power Supply Type
Switching (Closed Frame)
Voltage - Output
3.3V
Number Of Outputs
1
Power (watts)
600W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
3.3 VDC @ 120A
Size / Dimension
7.48" L x 4.72" W x 2.4" H (190mm x 120mm x 61mm)
Power (watts) - Rated
396W
Operating Temperature
-20°C ~ 74°C
Efficiency
72%
Approvals
CSA, DENAN, EN, IEC, UL
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
3.3V
Output Current
120A
Power Rating
396W
Input Voltage
85V AC To 265V AC / 120V DC To 350V DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
285-1789
SWS600L3

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SWS600L-3
Quantity:
115
Part Number:
SWS600L-36
Quantity:
120
・All specifications are subject to change without notice.
SWS
Before concluding that the unit is at fault, make the following
checks.
(1) Check if the rated input voltage is connected.
(2) Check if the wiring of input and output is correct.
(3) Check if the I/O terminal connection is properly tighten by
(4) Check if the wire thickness is enough.
(5) Check if the output voltage control (V.adj) is properly ad-
(6) If use function of the Remote ON/OFF control, check if the
(7) Check if the built-in FAN is not stopped. Is FAN stopped by
regulated torque.
justed. OVP might be trigged and output is shut down.
Remote ON/OFF control is properly used.
something irregular or etc?
600L, 1000L
10. Before concluding that the unit is at fault
(10) Check if the output current and output power does not over
(11) Audible noise can be heard when input voltage waveform
(12) Audible noise can be heard during dynamic load operation.
(8) Power supply has ventilating holes on the front and back
(9) Is the chassis of power supply hot abnormally? The output
If FAN stops, the ALM signal turn “High” level and OTP
might be activated.
panels. Check if there is any irregulars or dust, etc.
is shut down by OTP operation. Please re-input after the
unit is cooled down suffi ciently.