ZUP80-5/U TDK Corporation, ZUP80-5/U Datasheet - Page 23

PWR SUP BENCH PROG 0-80V 400W

ZUP80-5/U

Manufacturer Part Number
ZUP80-5/U
Description
PWR SUP BENCH PROG 0-80V 400W
Manufacturer
TDK Corporation
Series
ZUPr
Datasheets

Specifications of ZUP80-5/U

Voltage - Output
0 ~ 80V
Number Of Outputs
1
Power (watts)
400W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 80 VDC @ 5A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
400W
Operating Temperature
0°C ~ 50°C
Efficiency
87%
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.01%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
285-1686
ZUP805/U
3.8.2 Pin Description
Table 3-3: External Control connector pin description
3.8.3 External Control Connector - Technical description
1. Connector type : AMP, Part No: 5102617-5 14 contacts, double row.
2. Receptacle : AMP, Part No: 87631-9, Polarized, 14 contacts, double row.
3. Receptacle contacts : AMP, Part No: 87523-5 (strip form) or 87523-6 (loose piece).
4. Wires : AWG: 24 to 20.
5. Hand tool for wire connection : AMP, Part No: 90202-2.
6. Applicator for stripper/crimper machine : AMP, Part No: 466905-1
10
11
12 + S
13
14
COM pin (10) is connected internally to the - Sense potential. Connection of the COM to another
1
2
3
4
5
6
7
8
9
#
+ LS
RCVP
RCCP
VRFI
VCCP
VRFV
VCVP
OUTPUT
GOOD
P
ON/OFF
COM
- LS
Name
- S
potential or other than shown in this manual may cause damage to the power supply.
Description
Resistive Constant Voltage programming
Resistive Constant Current programming
Reference voltage for Constant Current control. (connected to
VCCP pin except external voltage or resistive programming).
Input of the Constant Current control circuit.
Reference voltage for Constant Voltage control. (connected to
VCVP pin except external voltage or resistive programming).
Input of the Constant Voltage control circuit.
Open collector output. 0~0.8V during normal operation, open at
fault condition (OVP, FOLD and Over-Temp.).
Parallel connection pin.
On/Off control pin.
Common pin for programming, On/off control and Output Good
signal. Internally connected to - Sense.
Positive Local sensing pin.
Positive Sensing pin for remote sense operation.
Negative Local sensing pin.
Negative Sensing pin for remote sense operation.
CAUTION
4.4.10
4.4.10
4.4.10, 11, 12
4.4.10, 11, 12
4.4.10, 11, 12
4.4.10, 11, 12
4.4.15
4.4.13
4.4.8
4.4.10, 11, 12
4.4.8
3.7.3, 4, 5, 6
3.7.3, 4, 5, 6
3.7.3, 4, 5, 6
3.7.3, 4, 5, 6
Par.