MPB80-2000 POWER ONE, MPB80-2000 Datasheet - Page 2

PWR SUP DUAL OUTPUT 80W,5V,12V

MPB80-2000

Manufacturer Part Number
MPB80-2000
Description
PWR SUP DUAL OUTPUT 80W,5V,12V
Manufacturer
POWER ONE
Series
MPB80r
Datasheet

Specifications of MPB80-2000

Voltage - Output
5V, 12V
Number Of Outputs
2
Power (watts)
80W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 11A
2nd Output
12 VDC @ 500mA
Size / Dimension
5" L x 3" W x 1.40" H (127mm x 76.2mm x 35.6mm)
Power (watts) - Rated
80W
Operating Temperature
0°C ~ 50°C
Efficiency
73%
Approvals
CE, CSA, EN, TUV, UL
Line Regulation
0.8%, 0.5%
Load Regulation
-4%, 2%; ±5%
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
4th Output
-
Other names
179-2013
MCD10094 Rev. 1.0, 21-Nov-08
Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-Up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
Output Specifications
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-On Delay
Turn-On Rise Time
Interface Signals and Internal Protection
PARAMETER
Overvoltage Protection
Overload Protection
CONDITIONS/DESCRIPTION
Autoranging AC input automatically adjusts, no manual strapping required.
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
After last AC line peak.
Single Output Models, 120 VAC
Single Output Models, 230 VAC
Dual and Triple Output Models, 120 VAC
Dual and Triple Output Models, 230 VAC
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 230 VAC (one cycle).
Switching frequency of main transformer.
CONDITIONS/DESCRIPTION
Full rated load, 230 VAC. Varies with distribution of loads among outputs.
Minimum load required on V1 for regulation of V2, V3.
Full load, 20 MHz bandwidth
Convection cooled, continuous output power.
Forced air cooled, 300 LFM, or convection cooled, peak
output power 10% duty cycle, 30 seconds maximum.
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes from 85-132 VAC or
170-264 VAC, changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100% load change,
5% max. deviation.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
CONDITIONS/DESCRIPTION
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
Page 2 of 4
All other Multiple Output Models
MPB80 AC-DC Series Data Sheet
Single Output Models
Full load @ 120 VAC
Full load @ 220 VAC
MPB80-10XX
MPB80-10XX
+5V, V1 & V2
MPB80-2000
MPB80-2000
MPB80-3000
MPB80-3300
MPB80-2000
MPB80-3000
MPB80-3300
+3.3V
12V
24V
48V
17.3
32.2
55.2
MIN
MIN
MIN
0.0
1.5
0.7
3.9
5.8
85
47
85
16
20
60
See Model Selection Chart
See Model Selection Chart
NOM
NOM
NOM
500
73
20
2
www.power-one.com
0.75
0.55
20.2
37.8
64.8
MAX
264
MAX
100
MAX
1.5
1.1
4.7
6.8
63
32
68
72
61
63
43
80
80
61
2
Amps
Watts
Watts
UNITS
A
UNITS
UNITS
VAC
VAC
A
kHz
Sec
ms
ms
Hz
RMS
µs
%
%
V
PK