2938976 Phoenix Contact, 2938976 Datasheet - Page 3

POWER SUPPLY 20A 100-240AC 48DC

2938976

Manufacturer Part Number
2938976
Description
POWER SUPPLY 20A 100-240AC 48DC
Manufacturer
Phoenix Contact
Series
Quintr
Type
Industrialr
Datasheets

Specifications of 2938976

Voltage - Output
48V
Number Of Outputs
1
Power (watts)
960W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
110 ~ 240VAC
Mounting Type
DIN Rail
1st Output
48 VDC @ 20A
Size / Dimension
4.92" L x 9.45" W x 5.12" H (125mm x 240mm x 130mm)
Power (watts) - Rated
960W
Operating Temperature
-25°C ~ 70°C
Efficiency
92%
Approvals
cUL, GOST, UL
Product
Switching
Commercial/medical
Commercial
Output Power Rating
960 W
Input Voltage
110 VAC to 240 VAC
Output Voltage (channel 1)
48 VDC
Output Current (channel 1)
20 A
Mounting Style
DIN Rail
Brand/series
QUINT-PS
Configuration
Enclosed
Operation
Switching
Output
48 VDC @ 20 A
Phoenix Part Number
QUINT-PS-100-240AC/48DC/20
Power, Output
80 W
Primary Type
AC-DC
Voltage, Input
85 to 264/90 to 350 VAC/VDC
Voltage, Output
48 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
277-1915
QUINT-PS-100-240AC/48DC/20
QUINT-PS-100-240AC/48DC/20
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2938976
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Operating voltage display
Efficiency
Insulation voltage input/output
Degree of protection
Class of protection
MTBF
Ambient temperature (operation)
Ambient temperature (storage/transport)
Max. permissible relative humidity (operation)
Mounting position
Assembly instructions
Electromagnetic compatibility
Emitted interference
Immunity to interference
Standard – Electrical equipment of machines
Standard - Safety of transformers
Standard - Electrical safety
Standard – Electronic equipment for use in
electrical power installations and their assembly
into electrical power installations
Standard – Safety extra-low voltage
Standard - Safe isolation
Standard – Protection against electric shock
Standard – Protection against shock currents,
basic requirements for protective separation in
electrical equipment
Standard – Limitation of mains harmonic currents
Standard – Equipment safety
Certificate
UL approvals
Surge voltage category
Order No.: 2938976
LED green
> 92 % (At 230 V AC and nominal values)
4 kV AC (type test)
2 kV AC (routine test)
IP20
I, with PE connection
> 500 000 h in acc. with IEC 61709 (SN 29500)
-25 °C ... 70 °C (> 60 °C derating)
-40 °C ... 85 °C
95 % (at 25 °C, no condensation)
Horizontal DIN rail NS 35, EN 60715
Can be aligned: Horizontal 0 cm, vertical 5 cm
Conformance with EMC guideline 2004/108/EC and for low-
voltage guideline 2006/95/EC
EN 50081-2
EN 61000-6-2:2005
EN 60204
EN 61558-2-17
EN 60950/VDE 0805 (SELV)
EN 61558-2-17
EN 50178/VDE 0160 (PELV)
EN 60950 (SELV)
EN 60204 (PELV)
DIN VDE 0100-410
DIN VDE 0106-1010
DIN 57100-410
DIN VDE 0106-101
EN 61000-3-2
GS (tested safety)
CB Scheme
UL/C-UL listed UL 508
UL/C-UL Recognized UL 60950
III
Mar 23, 2010
Page 3 / 7

Related parts for 2938976