* Read instruction manual carefully , before using the power supply unit.
* 1 : At Maximum Output Power, nominal input voltage, Ta = 25°C.
* 2 : For cases where conformance to various safety specs ( UL, CSA, EN ) are required, to be described as 100 - 240VAC, 50 / 60Hz on name plate.
* 3 : Not applicable for the in-rush current to Noise Filter for less than 0.2mS.
* 4 : Ripple&noise are measured at 20MHz by using a 300mm twisted pair of load wires terminated with a 0.1uF film capacitor and a 47uF electrolytic capacitor.
* 5 : Measure line & load regulation at output terminal M3.5 tapped point.
* 6 : 88 - 264VAC, constant load.
* 7 : No load - Full load (Maximum power ), constant input voltage.
* 8 : Current limit with automatic recovery. Avoid to operate at overload or dead short for more than 30 seconds.
* 9 : OVP circuit will shutdown output, manual reset (Re-power on).
* 10: Measured by each measuring method of UL and EN (at 60Hz), Ta=25°C.
* 11: Refer to Output Derating Curve (PA577-01-02_) for details of output derating versus ambient temperature.
* 12: All parameters NOT specifically mentioned are measured at 230VAC input, rated load and Ta = 25
* 13: Refer to Output Derating Curve (PA577-01-03_) for details of output derating versus input voltage.
10 Ripple and Noise
11 Line Regulation
12 Load Regulation
13 Temperature Coefficient
14 Over Current Protection
15 Over Voltage Protection
16 Hold-Up Time (Typ)
17 Leakage current
18 Series Operation
19 Operating Temperature
20 Operating Humidity
21 Storage Temperature
22 Storage Humidity
23 Cooling
24 Withstand Voltage
25 Isolation Resistance
26 Vibration
27 Shock (In package)
28 Safety
29 EMI
30 Immunity
31 Weight (Typ)
32 Dimension (L x W x H)
1
2
3
4
5
6
7
8
9
Nominal Output Voltage
Maximum Output Current
Maximum Output Power
Efficiency (Typ)
Input Voltage Range
Input Current (Typ)
Inrush Current (Typ)
Harmonic Current
Output Voltage Range
PA577-01-01
ITEMS
LS100
= NOTES=
(115/230VAC)
(115/230VAC)
(230VAC)
( * 2, 13 )
( * 5, 6 ) mV
( * 5, 7 ) mV
( * 1, 4 ) mV
( * 10 )
( * 11 )
( * 1 )
( * 1 )
( * 3 )
( * 8 )
( * 9 )
( * 1 )
MODEL
mm
mS
W
%
V
A
A
V
A
V
g
SPECIFICATIONS
LS100-3.3
3.8 ~ 4.45
Input - FG, Input - Output and Output - FG: More than 100MΩ (500VDC) at 25
3 ~ 3.6
3.3
20
66
75
80
20
40
88 ~ 264VAC (47-63Hz) or 125 ~ 373VDC (Withstand 300VAC Surge for 5 seconds)
5.75 ~ 6.75
4.75 ~ 5.5
LS100-5
Input - Output : 3.0kVAC (20mA), Input - FG : 1.5kVAC (20mA)
Built to meet EN61000-4-2 (Level 2,3), -3 (Level 3), -4 (Level 3),
16
80
79
80
20
40
5
Approved by UL60950-1, EN60950-1, IEC60950-1
- 25 ~ + 70 °C (Refer to Output Derating Curve)
At no operating, 10 - 55Hz (sweep for 1min)
Built to meet EN55011/EN55022-B, FCC-B
Output - FG : 500VAC (100mA) for 1min.
-5 (Level 4), -6 (Level 3), -8 (Level 4), -11
159 x 97 x 38 (Refer to Outline Drawing)
10.8 ~ 13.2
13.8 ~ 16.2 17.25 ~ 20.25 27.6 ~ 32.4
60A at 230VAC, Ta=25°C (Cold Start)
LS100-12
19.6m/s
102
120
8.5
Built to meet IEC61000-3-2, -3
12
82
48
96
20 ~ 90 %RH (No dewdrop)
10 ~ 95%RH (No dewdrop)
> 110% rated output power
< 1mA at 230VAC, 60Hz
2
Constant, X, Y, Z 1hour each.
Less than 196.1m/s
Less than 0.02%/°C
Convection cooling
o
C.
- 40 ~ +85°C
13.5 ~ 16.5
LS100-15
2.2 / 1.2
25 / 150
Possible
105
120
120
600
15
84
60
7
2
LS100-24
22 ~ 27.2
108
120
192
4.5
24
86
96
DENSEI-LAMBDA
41.4 ~ 48.6
LS100-36
32 ~ 40
108
150
144
288
36
86
3
o
C and 70%RH
55.2 ~ 64.8
LS100-48
42 ~ 54
110.4
200
192
384
2.3
48
86