ZPS4012 TDK Corporation, ZPS4012 Datasheet

PWR SUP AC-DC 12.0V 3.34A

ZPS4012

Manufacturer Part Number
ZPS4012
Description
PWR SUP AC-DC 12.0V 3.34A
Manufacturer
TDK Corporation
Series
ZP40r
Datasheets

Specifications of ZPS4012

Power Supply Type
Switching (Open Frame)
Voltage - Output
12V
Number Of Outputs
1
Power (watts)
40W
Applications
Commercial
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 3.34A
Size / Dimension
4" L x 2" W x 1.2" H (101.6mm x 50.8mm x 30.5mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 70°C
Efficiency
84%
Approvals
CE, CSA, EN, UL
Line Regulation
±0.5%
Load Regulation
±1%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
12V
Output Current
3.34A
Power Rating
40W
Input Voltage
90V AC To 264V AC / 120V DC To 370V DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
285-1649
ZPS40-12
Notes:
F e a t u r e s a n d B e n e f i t s
Feature
S p e c i f i c a t i o n s
ITEMS
Input Voltage range
Inrush Current (132/265VAC)
Input Current (115/230VAC)
Temperature Coefficient
Voltage Accuracy
Minimum Load
Load Regulation
Line Regulation
Ripple & Noise
Short Circuit Protection
Overvoltage Protection
Hold Up Time (Typ)
LED Indicator
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (WxLxH)
Warranty
(1) ZPD, ZPT for a 60% to 100% or 100% to 60% change in load
(2) ZPT40-3512N V2: ±3%, ZPS/ZPD40: 100-240VAC
(3) Measured with 0.1uF ceramic & 10uF electrolytic at 20MHz BW
Industry standard footprint
Up to 88% efficiency
Broad product range
Meets EN61000-4 immunity
(3)(4)
MODEL
(1)
(2)
(5)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
g (oz)
mV
ms
in
A
A
A
V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ZP40/60 Series
Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
ZPS40
23.52m/s
Green LED = OK
2 x 4" 40W to 60W AC-DC Power Supplies
0 to +70°C, derate linearly to 50% load from 50°C to 70°C
>100M at 25C & 70%RH, Output to Ground 500VDC
±0.5%
None
±1%
±1%
UL60950, CSA60950, EN60950, CE Mark (LVD)
2 x 4 x 1.2 (including underside components )
90 - 264VAC (47 - 440Hz) or 120 - 370VDC
2
(10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
Benefit
Computer Peripherals
Datacom
Point of Sale
Test and Measurement
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Availability to second source
Less system heating
Optimization of power supply to system
Greater reliability
(4) ZPT40-3512N, V1 & V2 100mV
(5) ZPS40 (3.3V to 9V models), ZPS60 (3.3V to 12V models) derate
1% or 50mV whichever is greater
Single and Multiple Outputs
Wide Range AC Input
Low profile, Industry Standard Footprint
Global Safety Agency Compliance
EN61000-4 Immunity
Typically 110-130% of nominal
ZPS60
linearly to 25% load from 40°C to 70°C
Continuous - hiccup mode
EN55022-B, FCC Class B
EN61000-4-2,-3,-4,-6,-8
8ms at 115VAC input
< 196.1 m/s
25 / 50 (cold start)
-20 to +85°C
10 - 95% RH
±0.05%/°C
Convection
170g (6oz)
One Year
1.6 / 1.0
2
(20G)
V1: ±3%, V2: ±4%, V3: ±3%
V1: ±3%, V2: ±5%, V3: ±1%
V1: ±1%, V2: ±2%, V3: ±1%
ZPD40
V1: 0.4A, V2: 0.2A
None
ZPT40
89

Related parts for ZPS4012

ZPS4012 Summary of contents

Page 1

Feature Industry standard footprint Up to 88% efficiency Broad product range Meets EN61000-4 immunity ...

Page 2

Max. Model O/P(V) O/P(A) ZPS40-3R3 V1 3.3 6.0 ZPS60-3R3 V1 3.3 8.0 ZPS40-5 V1 5.0 6.0 ZPS60-5 V1 5.0 8.0 ZPS40-9 V1 9.0 4.45 ZPS60-9 V1 9.0 ...

Related keywords