SWT40-5FF TDK Corporation, SWT40-5FF Datasheet - Page 14

PWR SUP 40W +5 +15 -15V TRIPLE

SWT40-5FF

Manufacturer Part Number
SWT40-5FF
Description
PWR SUP 40W +5 +15 -15V TRIPLE
Manufacturer
TDK Corporation
Series
SWT40r
Datasheets

Specifications of SWT40-5FF

Voltage - Output
5V, ±15V
Number Of Outputs
3
Power (watts)
40W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 3A
2nd Output
15 VDC @ 1.5A
3rd Output
-15 VDC @ 300mA
Size / Dimension
5" L x 3" W x 1.4" H (127mm x 76.2mm x 35.6mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 50°C
Efficiency
70%
Approvals
CSA, DENAN, EN, UL
Line Regulation
1%, 2%
Load Regulation
2%, 4%
4th Output
-
Other names
285-1073
SWT405FF
Alpha II
ZWD-
Genesys
ZWS-
FPS
HK-A
HWS
MTW
RKE
RTW
UNA
ZWQ
DLP
JWS-P
RKY
SWT
VS-P
ZUP
ZWS
JWT
PAF
PAF
VS
A-286
SWT
Isolation resistance between output and FG shall be more
than 100MΩ at 500VDC. For safety operation, voltage
setting of DC isolatin tester must be done before the test.
Ensure that it is fully discharged after the test.
This series is designed to withstand 3.0kVAC between
input and output, 2.5kVAC between input and FG and
500VAC between output and FG for 1 minute. When test-
ing withstand voltage, set current limit of the withstand
Please use the mounting hole and insert the spacer (MAX
φ6.0mm) of height over 8mm to lift the unit. The vibration
spec is the value taken when the unit is raised by 8mm
specers.
Isolation Test
Withstand Voltage
Output-FG
SWT30,SWT40,SWT65‥‥
SWT100‥‥5 pcs(φ3.5mm)
SERIES
AC(L)
AC(N)
FG
HEIGHT MORE
THAN 8mm
4 pcs
+5V
GND
3. Mounting Method
(φ3.5mm)
+V
−V
voltage test equipment to 20mA (Output-FG: 100mA). The
applied voltage must be gradually increased from zero to
the testing value and then gradually decreased for shut
down. When timer is used, the power supply may be dam-
aged by high impulse voltage at timer switch on and off.
Connect input and output as follows. When output is left
open during tests, output voltage might appear momen-
tarily.
When mounting this unit (PCB), please allot space to sat-
isfy isolation and withstand voltage specifications. Further-
more, for convection cooling, component side ventilation is
necessary.
FG should be connected to the earth terminal of the appa-
ratus. If not, the EMI noise and output noise will increase.
NO LESS THAN 4mm
NO LESS THAN 4mm
WIRE
(20mA)
2.5kVAC
1 min
NO LESS THAN 4mm
NO LESS THAN 4mm
Please left 4mm space from the surfaces and the
sides of PCB, especially from the solder surface,
8mm space is necessary.
Output-FG
Input-FG (solid line)
Input-Output (dotted line)
NO LESS THAN 4mm
500VAC 1 min(100mA)
・All specifications are subject to change without notice.
FG
FG
3kVAC 1 min(20mA)
NO LESS THAN 8mm
FG
AC(L)
AC(N)
AC(L)
FG
AC(N)
METAL SPACERS
NO LESS THAN 4mm
+5V
GND
NO LESS THAN 4mm
+5V
GND
+V
−V
+V
−V

Related parts for SWT40-5FF