SWT65-5FF TDK Corporation, SWT65-5FF Datasheet

PWR SUP 65W +5 +15 -15V TRIPLE

SWT65-5FF

Manufacturer Part Number
SWT65-5FF
Description
PWR SUP 65W +5 +15 -15V TRIPLE
Manufacturer
TDK Corporation
Series
SWT65r
Datasheets

Specifications of SWT65-5FF

Voltage - Output
5V, ±15V
Number Of Outputs
3
Power (watts)
65W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 132VAC, 170 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 6A
2nd Output
-15 VDC @ 1.8A
3rd Output
-15 VDC @ 500mA
Size / Dimension
6" L x 3.5" W x 1.77" H (152.4mm x 88.9mm x 45mm)
Power (watts) - Rated
65W
Operating Temperature
0°C ~ 50°C
Efficiency
72%
Approvals
CSA, DENAN, EN, UL
Line Regulation
1%, 2%
Load Regulation
2%, 4%
Brand/series
SWT65 Series
Operation
Linear
Output
-15 VDC @ 0.5 A, +5 VDC @ 6 A, +15 VDC @ 1.8 A
Power, Output
64.5 W
Primary Type
AC-DC
Voltage, Input
85 to 132/170 to 265 VAC
Voltage, Output
-15, +5, +15 VDC
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1076
SWT655FF
CA703-01-01B
*1.
*2.
*3.
*4.
*5.
*6.
*7.
*8.
*9.
*10. Peak current operation is less than 10 sec. with duty factor less than 30%.
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
SWT65 Specifications
10 Output Voltage
11 Maximum Ripple & Noise
12 Maximum Line Regulation
13 Maximum Load Regulation
14 Maximum Temperature Drift
15 Over Current Protection
16 Over Voltage Protection
17 Hold-up Time (Typ)
18 Operating Temperature
19 Operating Humidity
20 Storage Temperature
21 Storage Humidity
22 Cooling
23 Withstand Voltage
24 Isolation Resistance
25 Vibration
26 Shock
27 Output Grounding
28 Safety
29 EMI
30 Radiated Emission
31 Weight
32 Size (WxHxD)
1 Nominal Output Voltage
2 Minimum Output Current
3 Maximum Output Current
4 Peak Output Current
5 Maximum Output Power (Peak)
6 Efficiency (Typ)
7 Input Voltage Range
8 Input Current (Typ)
9 Inrush Current(Typ)
ITEMS
At 100VAC/ 200VAC and Maximum. Output power (Convection cooling), Ta=25°C.
For cases where conformance to various safety specs (UL,CSA, EN) are required
to be described as 100-120VAC, 200-240VAC, 50/60 Hz on name plate.
Please refer to Fig A for measurement determination of line & load regulation and output ripple voltage.
From 85 - 132VAC / 170 - 265VAC, constant load.
From Min. load - Full load ( Maximum power ), constant input voltage.
From 0°C - +50°C, constant input voltage and load.
Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds.
Over voltage clamping by zener diode.
At standard mounting method, Fig B.
In addition, it does not has to satisfy the total regulation specification.
MODEL
UL1950
CSA950
EN60950
DENTORI
(*3,4) - CH 1: 1%, CH2 : 2%, CH3 : 1%
(*3,5) - CH 1: 2%, CH2 : 4%, CH3 : 2%
(*3,6) - 0.04% / °C
(*10) A
(*1) - 72%
(*2) - 85 - 132VAC / 170 - 265VAC (auto selectanle), 47 - 63Hz
(*1) - 1.71A (Vin=100VAC) / 0.86A (Vin=200VAC)
(*3) - ±5V:120mV, ±12V:150mV, ±15V:150mV
(*7) - Automatic recovery, O.C.P point : 105% -
(*8) - 6V - (CH1 only)
(*1) - 17ms (Input 100VAC)
(*9) - Convection cooling 0 - +50°C : 100% load, +60°C : 70% load
mm 88.9 x 152.4 x 45 ( Refer to Outline Drawing )
inch
W
V
A
A
g 350
- 30A / 100VAC, 30A / 200VAC (cold start Ta=25°C )
-
-
- -20 - +85°C
-
- Convection Cooling
- Input - Output : 3kVAC (20mA), Input - FG : 2.5kVAC (20mA)
- More than 100M at 25°C and 70%RH , Output - FG : 500VDC
- 10 - 55Hz Amplitude (Sweep for 1min). Less than 2G, X,Y,Z 1hour each.
- Less than 20G
- All channels common ground ( 2 terminals )
- Approved
- Approved
- Approved
- Built to meet
- Built to meet EN55011-B,EN55022-B, FCC-ClassB, VCCI-2.
- Built to meet EN55011-B,EN55022-B, FCC-ClassB, VCCI-2.
Shipment condition : CH1:±1%, CH2(+12V) :±3%, CH2(+15V) :±5%, CH3 :±5%
Output - FG : 500VAC (100mA) for 1min
3.50 x 6.00 x 1.77( 3.15 x 4.80 mounting hole 3.5mm )
CH1 (+5V) Fixed, CH2,3 Fixed
30 - 90%RH (No dewdrop)
10 - 95%RH (No dewdrop)
CH1
0.3
+5
6
-
SWT65-522
CH2
+12
2.5
66
0
*
-
CH3
-12
0.5
0
-
CH1
0.3
+5
6
-
SWT65-525
CH2
62.5
+12
2.5
0
*:For delivery, contact to our sales office.
*
-
CH3
0.5
-5
0
-
CH1
0.3
+5
6
-
NEMIC-LAMBDA
SWT65-5FF
CH2
64.5
+15
1.8
0
*
-
CH3
-15
0.5
0
-

Related parts for SWT65-5FF

SWT65-5FF Summary of contents

Page 1

... Built to meet - Built to meet EN55011-B,EN55022-B, FCC-ClassB, VCCI-2. - Built to meet EN55011-B,EN55022-B, FCC-ClassB, VCCI-2. g 350 mm 88.9 x 152 Refer to Outline Drawing ) inch 3.50 x 6.00 x 1.77( 3.15 x 4.80 mounting hole 3.5mm ) NEMIC-LAMBDA *:For delivery, contact to our sales office. * SWT65-525 SWT65-5FF CH1 CH2 CH3 CH1 CH2 +5 + +15 ...