LWT-30H-525 TDK Corporation, LWT-30H-525 Datasheet

POWER SUP 30W +5 +12 -5V TRIPLE

LWT-30H-525

Manufacturer Part Number
LWT-30H-525
Description
POWER SUP 30W +5 +12 -5V TRIPLE
Manufacturer
TDK Corporation
Series
LWr
Datasheets

Specifications of LWT-30H-525

Power Supply Type
Switching (Open Frame)
Voltage - Output
±5V, 12V
Number Of Outputs
3
Power (watts)
30W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 5A
2nd Output
12 VDC @ 1.2A
3rd Output
-5 VDC @ 600mA
Size / Dimension
6.29" L x 2.75" W x 0.98" H (160mm x 70mm x 25mm)
Power (watts) - Rated
30W
Operating Temperature
0°C ~ 60°C
Efficiency
73%
Approvals
CE, CSA, EN, UL, VDE
Line Regulation
1%
Load Regulation
2%
Power Supply Output Type
Fixed
No. Of Outputs
3
Output Voltage
5V
Output Current
5A
Power Rating
30W
Input Voltage
85V AC To 265V AC / 110V DC To 330V DC
Length
160mm
4th Output
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
285-1020
LWT30H-525
LWT30H525
F e a t u r e s a n d B e n e f i t s
Feature
S p e c i f i c a t i o n s
ITEMS
Max Output Power (typ)
Efficiency (Typ)
AC Input Voltage range
DC Input Voltage range
Input Current Typ (100/200VAC)
Inrush Current (110/200VAC)
Output 1 Voltage Adjustment
Output Voltage Accuracy
Temperature Coefficient
Line Regulation
Load Regulation
Ripple & Noise
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ at 100VAC)
Series Operation
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted EMI
Weight (Typ)
Size (WxHxD)
Warranty
* LWT models only
Note: See Installation Manual for full details, test methods of parameters and application notes
Low Profile
Isolated 2nd and 3rd outputs
Wattbox design on LWT
MODEL
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
mm
ms
°C
W
%
A
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Input to Gnd, Input to Output 2kVAC (20mA)
5V:100mV , 12V & 15V: 150mV , 24V: 200mV
0.4/0.2
LWD15
17/34
180
15
64
LWD: 0°C to +60°C, derate as follows: 40°C: 100%, 50°C: 60%, 60°C: 40%
LWT: 0°C to +60°C, derate as follows: 40°C: 100%, 50°C: 80%, 60°C: 60%
Output 2 ±5%
FCC Class A
19.6m/s
-
>100M at 25C & 70%RH, Output to Ground 500VDC
5V: 5 to 5.25V, 12V: 12 to 12.6V, 15V: 15V to 15.75V
110 - 350VDC
Output 1 < 1%, Output 2 or 3, <2% at 0 - 60°C
0.72/0.36
2
LWD30
Main output only: 5.75 - 6.75V, manual reset
14/28
250
30
70
Benefit
Factory Automation
Test & Measurement
Automated Service
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Assists System Integration
Enable series operation for higher voltages
Power trading between outputs
Not recommended for new design highlighted in green
Low Profile Dual & Triple Output
30 - 90% RH (Non condensing)
10 - 95% RH (Non condensing)
Please refer to outline drawings
26mm height
Outputs 2 and 3 isolated from output 1
Universal Input (85 - 265VAC)
85 - 265VAC (47 - 440Hz)
LW Series
-30 to +85°C
Convection
UL60950-1, CSA60950-1, EN60950-1, CE LVD
196.1m/s
One Year
0.4/0.22
LWT15H
Possible
>105%
14/28
Output 1: 100mV, Outputs 2 & 3: 150mV
220
Input to Gnd 2kVAC Input to Output 3kVAC (20mA)
1%
2%
17
72
20
10-55Hz(1 min) <19.6m/s
2
VDE Class B, FCC Class B
Process Control, NC-Machining,
Automotive, Packaging Equipment,
Materials Handling,
Chemical Processing, Robots
Burn-in & Test, Automated
Test, Instrumentation,
Measurement, Detection
Vending Machines, Elevators,
Video Gaming, Point of Sale Equipment
Output 2 & 3 ±5%
0.7/0.42
LWT30H
16/32
300
30
73
*
2
110 - 330VDC
(1 hr)
LWT50H
1.2/0/7
16/32
400
50
72
61

Related parts for LWT-30H-525

LWT-30H-525 Summary of contents

Page 1

... Main output only: 5.75 - 6.75V, manual reset LWD: 0°C to +60°C, derate as follows: 40°C: 100%, 50°C: 60%, 60°C: 40% LWT: 0°C to +60°C, derate as follows: 40°C: 100%, 50°C: 80%, 60°C: 60 90% RH (Non condensing 95% RH (Non condensing) Input to Gnd, Input to Output 2kVAC (20mA) > ...

Page 2

... DIMENSIONS: MODEL A B 0.0 0.6 5.03 .31 LWT-15 0.0 1.2 (128.0) (7.9) 6.29 .47 LWT-30 0.0 1.2 (160.0) (12.0) 6.29 .35 0.0 1.2 LWT-50 (159.7) (8.8) 0.0 0.6 4.32 .31 LWD-15 (7.9) (109.7) 0.0 1.0 5.75 .48 LWD-30 (146.0) (12.1) 0.0 1.0 6.29 .35 LWD-50 (8.8) 0.5 3 ...

Related keywords