SWS600L-36 TDK Corporation, SWS600L-36 Datasheet - Page 14

POWER SUPPLY 36V 18A SGL OUTPUT

SWS600L-36

Manufacturer Part Number
SWS600L-36
Description
POWER SUPPLY 36V 18A SGL OUTPUT
Manufacturer
TDK Corporation
Series
SWSr
Type
Commercialr
Datasheets

Specifications of SWS600L-36

Power Supply Type
Switching (Closed Frame)
Voltage - Output
36V
Number Of Outputs
1
Power (watts)
600W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
36 VDC @ 18A
Size / Dimension
7.48" L x 4.72" W x 2.4" H (190mm x 120mm x 61mm)
Power (watts) - Rated
648W
Operating Temperature
-20°C ~ 74°C
Efficiency
84%
Approvals
CSA, DENAN, EN, IEC, UL
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
36V
Output Current
18A
Power Rating
648W
Input Voltage
85V AC To 265V AC / 120V DC To 350V DC
Brand/series
SWS Series
Configuration
Enclosed
Output
36 VDC @ 18 A
Power, Output
648 W
Primary Type
AC-DC
Special Features
Parallelable, PFC, Remote On/Off, Remote Sense
Voltage, Input
85 to 265/120 to 350 VAC/VDC
Voltage, Output
36 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1790
SWS600L36

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SWS600L-36
Quantity:
120
14
SWS
Method (A)
Method (B)
Isolation resistance between output and
more than 50MΩat 500VDC and between output and AUX,
CNT, ALM shall be more than 50M
operation, voltage setting of DC isolation tester must be done
before the test. Ensure that it is fully discharged after the test.
change about 400mV (3V, 5V), 5% (12V, 15V, 24V, 36V, 48V,
60V) in its transient response.
Isolation Test
Output - FG (chassis) : 500VDC 50MΩ or more
PC COM
PC COM
Power Supply
Power Supply
600L, 1000L
Isolation
Tester
+Vm
-Vm
+Vm
-Vm
+S
+S
-S
-S
+Vm
+Vm
-Vm
-Vm
+S
+S
-S
-S
Vo+Vf
Vo+Vf
AC(L)
AC(N)
Output Power (W) = (Vo+Vf) ×IO
Io
Vo
Ω
at 100VDC. For safety
CNT1
CNT2
COM
+Vm
TOG
ALM
AUX
-Vm
+S
PC
PV
G1
G2
-S
+
-
Load
(chassis) shall be
Load
SWS600L is designed to withstand 3.0kVAC, SWS1000L is de-
signed to withstand 4.0kVAC between input and output. This
series is designed to withstand 2.0kVAC between input
and
100VAC between output and CNT, AUX, ALM terminal each for
1 minute. When testing withstand voltage, set current limit of
withstand voltage test equipment at 20mA.
(Output -
The applied voltage must be gradually increased from zero
to testing value and then gradually decreased for shut down.
When timer is used, the power supply may be damaged by high
impulse voltage at timer switch on and off. Connect input and
output as follows.
Withstand Voltage
Input - (chassis) (solid line) : 2.0kVAC 1min. (20mA)
Input - Output (dotted line): 3.0kVAC 1min. (20mA),
(chassis), 500VAC between output and
Output - CNT・AUX・ALM : 100VDC 50MΩ or more
Output -
Withstand
Voltage
Tester
(chassis) and Output - Control : 100mA).
(SWS600L-60: 651VAC 1min 130mA)
(SWS1000L: 4.0kVAC 1min 20mA)
Withstand
Voltage
Tester
AC(L)
AC(N)
(chassis) : 500VAC 1min. (100mA),
・All specifications are subject to change without notice.
AC(L)
AC(N)
CNT1
CNT2
AC(L)
AC(N)
COM
+Vm
TOG
ALM
AUX
-Vm
PC
PV
G1
G2
+S
-S
+
-
Isolation
Tester
CNT1
CNT2
COM
TOG
ALM
+Vm
AUX
-Vm
PC
+S
PV
G1
G2
-S
+
-
CNT1
CNT2
COM
+Vm
TOG
ALM
AUX
-Vm
PC
G1
G2
+S
PV
-S
+
-
(chassis), and