HWS600-12/HD TDK Corporation, HWS600-12/HD Datasheet

PWR SUP IND 12V 636W 53A

HWS600-12/HD

Manufacturer Part Number
HWS600-12/HD
Description
PWR SUP IND 12V 636W 53A
Manufacturer
TDK Corporation
Series
HWSr
Type
Open Framer
Datasheets

Specifications of HWS600-12/HD

Power Supply Type
Switching (Closed Frame)
Voltage - Output
12V
Number Of Outputs
1
Power (watts)
600W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 53A
Size / Dimension
6.5" L x 3.94" W x 3.23" H (165.1mm x 100.1mm x 82mm)
Power (watts) - Rated
636W
Operating Temperature
-10°C ~ 71°C
Efficiency
83%
Approvals
CE, CSA, IEC, EN, UL
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
12V
Output Current
53A
Power Rating
636W
Input Voltage
85V AC To 265V AC / 120V DC To 330V DC
Output Current (max)
53A
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Depth (mm)
100mm
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
71C
Mounting Style
Chassis
Pin Count
7
Brand/series
HWS Series
Configuration
Enclosed
Operation
Switching
Output
12 VDC @ 53.00 A
Power, Output
636 W
Primary Type
AC-DC
Special Features
Parallelable, PFC, Remote On/Off, Remote Sense
Voltage, Input
85 to 265/120 to 330 VAC/VDC
Voltage, Output
12 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Compliant
Other names
285-1360
HWS60012/HD

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HWS600-12/HD
Quantity:
81
F e a t u r e s a n d B e n e f i t s
Feature
S p e c i f i c a t i o n s
ITEMS
Input Voltage range (47-63Hz)
Input Current (Typ)
Inrush Current
Power Factor
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ)
Leakage Current (60Hz)
Remote Sense
Indicator
Remote On/Off
Parallel operation
DC Good
Remote Adjust (PV)
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock (in packaging)
Safety Agency Approvals
Line Dip
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (WxHxD)
Warranty
(1)
(2)
Limited Lifetime Warranty
Conformally coated pcbs
Wide range AC Input
and Derating (operation to
+74°C - contact factory)
100/200VAC input
HWS300-600 2.5kVAC Input to ground
MODELS
(1)
(1)
(2)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
HWS50-1500/HD
mA
ms
°C
in
yr
A
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.04x3.23x4.72 1.1x3.23x6.3 1.46x3.23x6.3 2.4x3.23x6.5 3.94x3.23x6.5
>100MΩ at 25°C & 70%RH, Output to Ground 500VDC, >10M Output to remote on/off 100VDC
0.7 / 0.35
HWS300-1500: -10°C to +71°C, (-10 ~+50°C: 100%, derate linearly to 50% load from +50 to +71°C)
HWS50
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
280
No
Guaranteed start up at -40°C (see specification sheets on website for details and derating)
Operating: 30 - 90%RH (10 -90% on HWS300-1500), Non operating 10 - 95%RH
85-265VAC or 120-370VDC
HWS50-150: -10°C to +71°C, (-10 ~+50°C: 100%, +60°C: 60%, +71°C: 20%)
MIL-STD-810F 514.5 Category 4, 10 (HWS1500 Cat 4, figure 514.5C-1)
IEC61000-4-2 (Level 2,3), -3, -4, -6, (Level 3), -5, -8 (Level 4), -11
Convection
1.3 / 0.65
HWS100
<0.5mA
MIL-STD-810F 516.5 Category I, VI (HWS1500 <196.1m/s
EN55011 / EN55022-B, FCC-B, VCCI-B (HWS1500 Class A)
14 / 28
UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark
Limited lifetime warranty (See Lambda’s terms & conditions)
Single Output Industrial Power Supplies
450
No
No
No
Complies with SEMI F47 (200VAC line only)
Benefit
Factory Automation
LED Displays
1.9 / 0.95
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Lower Cost of Ownership
Operation in harsh environments
Supports global use
HWS150
(3)
(*)
Limited Lifetime Warranty
-10 to +71°C Operation (-40°C start up)
Universal Input (85 - 265VAC)
Conformally coated pcbs
Class 1 Div 2 option (/RYHD suffix)
500
No
Yes (See table on page 2)
1-6V program voltage input to adjust output 20-120% (typical) of
nominal. See instruction manual for details & models with this feature.
Class 1 Div 2 option (/RYHD suffix)
Meets EN61000-3-2
Green LED = ON
-40 to +85°C
<0.02%/°C
85-265VAC or 120-330VDC (No DC input for HWS1500)
4.1 / 2.1
HWS300
>104%
1000
20
Yes
<0.75mA
Single wire connection (5 units max)
Test & Measurement
Yes (Isolated from output)
8.1 / 3.9
HWS600
1600
Internal fan
20 / 40
Yes
HWS1000
5x3.2x9.5
<1.2mA
13.5 / 7
3200
2
)
Yes (3)
5x3.25x11
HWS1500
≤1.5mA
19 / 10
3800
45

Related parts for HWS600-12/HD

HWS600-12/HD Summary of contents

Page 1

... See instruction manual for details & models with this feature. (*) Class 1 Div 2 option (/RYHD suffix) Test & Measurement HWS300 HWS600 HWS1000 85-265VAC or 120-330VDC (No DC input for HWS1500) 4.1 / 2.1 8.1 / 3.9 13 <0.02%/°C > ...

Page 2

... HWS1000-7/HD 7.5V 6.0 - 9.0 HWS50-12/HD 12V 9.6 - 14.4 HWS100-12/HD 12V 9.6 - 14.4 HWS150-12/HD 12V 9.6 - 14.4 HWS300-12/HD 12V 9.6 - 14.4 HWS600-12/HD 12V 9.6 - 14.4 HWS1000-12/HD 12V 9.6 - 14.4 HWS1500-12/HD 12V 9.6 - 14.4 HWS50-15/HD 15V 12.0 - 18.0 HWS100-15/HD 15V 12.0 - 18.0 HWS150-15/HD 15V 12 ...