ZUP120-3.6/U TDK Corporation, ZUP120-3.6/U Datasheet - Page 37

PWR SUP BENCH PROG 0-120V 432W

ZUP120-3.6/U

Manufacturer Part Number
ZUP120-3.6/U
Description
PWR SUP BENCH PROG 0-120V 432W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Enclosedr
Datasheets

Specifications of ZUP120-3.6/U

Number Of Outputs
1
Efficiency
87%
Voltage - Output
0 ~ 120V
Power (watts)
432W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 120 VDC @ 3.6A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
432W
Operating Temperature
0°C ~ 50°C
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.01%
Output Current (max)
3.6A
Input Voltage
85 to 265V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
285-1672
ZUP1203.6/U
4. OUTPUT VOLTAGE PROGRAMMING BY EXTERNAL RESISTOR
Fig 4-5 shows a typical set-up for programming the output voltage. A variable programming resistor,
0~4Kohm produces a proportional output voltage from zero to full scale. In order to set the low limit, a
series resistor can be connected to the programming resistor. For example; a 1kohm series resistor will
set the lower limit to 25% of full scale. In order to set the upper limit, a resistor can be connected in
parallel to the programming resistor. The resultant programming resistance of the series/parallel
resistors must be between 0 and 4Kohm.
Fig. 4-5:
Constant voltage resistive programming.
Fig. 4-6:
Constant current resistive programming.
5.OUTPUT CURRENT PROGRAMMING BY EXTERNAL RESISTOR
Fig 4-6 shows the set-up for constant current resistive programming. The explanation given for
constant voltage resistive programming also applies for constant current.
Resistive programming is possible for local and remote sensing.
sets lower
sets lower
Optional
Optional
limit
limit
programming resistor
programming resistor
0~4K
0~4K
NOTE
sets upper limit
sets upper limit
Optional
Optional
VCVP
VCCP
RCCP
COM
VCVP
VCCP
RCCP
External control connector
External control connector
- S
+S
COM
P
(ZUP rear panel view)
(ZUP rear panel view)
- S
+S
P
14
14
2
2
13
1
13
1
Output Good
Output Good
On/Off
VRFV
VRFI
RCVP
On/Off
VRFV
VRFI
RCVP
- LS
+LS
- LS
+LS

Related parts for ZUP120-3.6/U