HCAA-60W-AG POWER ONE, HCAA-60W-AG Datasheet - Page 5

LNR SUP TRL OUT 5V/6A

HCAA-60W-AG

Manufacturer Part Number
HCAA-60W-AG
Description
LNR SUP TRL OUT 5V/6A
Manufacturer
POWER ONE
Series
Linearr
Type
Open Framer
Datasheets

Specifications of HCAA-60W-AG

Voltage - Output
5V, -12V, 15V
Number Of Outputs
3
Power (watts)
30W
Applications
Commercial
Power Supply Type
Linear, Regulated (Open Frame)
Voltage - Input
100, 120, 220, 240VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 6A
2nd Output
15 VDC @ 1A
3rd Output
-12 VDC @ 1A
Size / Dimension
9" L x 4.87" W x 3.28" H (228.6mm x 123.7mm x 83.3mm)
Power (watts) - Rated
30W
Operating Temperature
0°C ~ 50°C
Efficiency
45%
Approvals
CE, CSA, cUL, EN, IEC, TUV, UL
Line Regulation
±0.05%
Load Regulation
±0.05%
Output Current (max)
6/15/15A
Input Voltage
100 to 240V
Output Voltage
5/12/-12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
228.6mm
Product Height (mm)
83.31mm
Product Depth (mm)
123.7mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Screw
Package / Case
Case D
Product
Linear
Commercial/medical
Commercial
Output Voltage (channel 1)
+ 5 V
Output Current (channel 1)
6 A
Output Voltage (channel 2)
+ 12 V
Output Current (channel 2)
1 A
Output Voltage (channel 3)
- 5 V
Output Current (channel 3)
0.4 A
Dimensions
228.6 mm L x 123.7 mm W x 83.31 mm H
Open Frame/enclosed
Open Frame
Case Type
D
Configuration
Open-Frame
Frequency, Input
47 to 63 Hz
Operation
Linear
Output
-5 VDC @ 0.4 A, +5 VDC @ 6 A, +12 VDC @ 1 A
Output Type
Triple Output
Primary Type
AC-DC
Special Features
Remote Sense
Standards
UL Listed, CSA Certified, CE Marked and TÜV Approved
Temperature, Operating
0 °C
Time, Response
50 us (Max.)
Voltage, Input
100 to 264 VAC
Voltage, Output
-5, +5, +12 VDC
Voltage, Output 1
5 VDC
Voltage, Output 2
+12 to +15 VDC
Voltage, Output 3
-5 VDC
Worldwide Ac Input Capabilities
100/120/220/230/240 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2326

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCAA-60W-AG
Manufacturer:
PowerOne
Quantity:
119
Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Line Regulation
NOTES:
Output Specifications
PARAMETER
Output Adjustment
Efficiency
Ripple and Noise
Load Regulation
Transient Response
NOTES:
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand
Voltage
Electromagnetic
Interference
Leakage Current
Interface Signals and Internal Protection
PARAMETER
Overvoltage Protection
Remote Sense
Overcurrent/Short Circuit
Protection
Master/Slave Operation
MCD10016 Rev. 1.2, 13-Nov-09
(Note 1, 2)
(Note 2)
1) Derate output current 10% for 50Hz operation.
2) Input voltage tolerance for 230VAC operation is +15%, -10%.
1) OUTPUT VOLTAGE ADJUSTMENTS:
2) Full load, 20MHz bandwidth.
potentiometer on the power supply PCB and use a screwdriver to adjust the output pot. The HAD12 and HAD15 3 terminal regulator outputs are not
adjustable.
CONDITIONS/DESCRIPTION
Jumper selectable, shipped factory configured for
120VAC operation. All models must be externally
fused for proper operation. Fuse ratings are marked
on each unit. Consult factory for each unit’s fuse
requirements.
AC input.
Output voltage charge for a 10% line change: F case models.
HAD12, HAD15.
Outputs with adjustable three terminal regulators.
All other models.
CONDITIONS/DESCRIPTION
Minimum output adjustment range (Note 1).
5 volt outputs.
12 volt and 15 volt outputs.
24 volt and higher outputs.
F case models.
5 volt, 12 volt, and 15 volt models.
All three terminal regulator outputs.
24 volt through 250 volt models.
Output change for a 50% load change: F case models.
HAD12, HAD15.
Outputs with adjustable three terminal regulators.
All other models.
Recovery time, to within 1% of initial set point due to a 50% load change.
CONDITIONS/DESCRIPTION
UL60950-1.
CSA 60950-1 “cUL”.
EN60950-1.
IEC60950-1.
Input to output.
Input to ground.
FCC CFR title 47 Part 15 Sub-Part B - conducted.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
Per EN60950
CONDITIONS/DESCRIPTION
Provided on 5 volt output units where indicated.
Other outputs may use optional overvoltage protectors OVP-12 and OVP-24.
Total voltage compensation for cable losses with respect to the main output.
Provided on models where indicated.
Automatic current limit/foldback. Rated as a percentage of output power.
For parallel operation of up to 6 units. Master/slave pin provided on F case models only. Contact factory for application notes.
Output voltage adjustments can be made to within ±5% of factory setting of nominal output voltage. Locate the “Vadj”
Page 5 of 9
(264VAC)
Linear Power Supplies Data Sheet
100 VAC Tap
120 VAC Tap
220 VAC Tap
240 VAC Tap
3.0mV
Compatible with system compliance to Level B.
PK-PK
-0.01
-0.05
-0.02
-0.05
3000
1500
-1.0
-0.5
-0.5
MIN
104
191
209
MIN
115
MIN
MIN
5.8
87
47
-5
-1
plus 0.02% of output voltage, max
NOM
NOM
100
120
220
240
NOM
NOM
120
45
55
60
23
Approved
www.power-one.com
+0.01
+0.05
+0.02
+0.05
+1.0
+0.5
+0.5
MAX
MAX
110
132
242
264
MAX
MAX
250
140
3.0
5.0
0.2
6.6
63
+5
+1
50
50
mV
mV
%
UNITS
UNITS
UNITS
UNITS
VAC
VAC
PK-PK
mV
Hz
μA
%
%
%
PK-PK
PK-PK
%
μ
%
V
s

Related parts for HCAA-60W-AG