PWR SUP 1812W 48V FRONT END

FNP1800-48G

Manufacturer Part Number
FNP1800-48G
Description
PWR SUP 1812W 48V FRONT END
Manufacturer
POWER ONE
Series
FNP1800r
Type
Commercial, Industrialr
Datasheets

Specifications of FNP1800-48G

Voltage - Output
12V, 48V
Number Of Outputs
2
Power (watts)
1800W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 39.2A
2nd Output
12 VDC @ 1A
Size / Dimension
11" L x 1.6" W x 5.6" H (279.4mm x 40.5mm x 141.2mm)
Power (watts) - Rated
1812W
Operating Temperature
0°C ~ 50°C
Efficiency
90%
Approvals
CE, cUL, EN, TUV, UL
Product
Switching
Commercial/medical
Commercial
Output Power Rating
1546 W
Input Voltage
85 VAC to 264 VAC
Output Voltage (channel 1)
48 V
Output Current (channel 1)
39.2 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
1 A
Mounting Style
Rack
Dimensions
11 in L x 5.6 in W x 1.6 in H
Brand/series
FNP1800 Series
Configuration
Enclosed
Operation
Linear
Output
12 VDC @ 1 A, 12 VDC @ 1 A, 12 VDC @ 1 A, 48 VDC @ 25.4 A, 48 VDC @ 32.2 A, 48 VDC @ 39.2 A
Power, Output
1812, 1512, 1212 W
Primary Type
AC-DC
Special Features
PFC
Voltage, Input
230 VAC
Voltage, Output
12, 12, 12, 48, 48, 48 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2397
Safety Specifications
Maximum electric strength testing is performed in the factory according to EN 550116, IEC/EN 60950, and UL 60950.
Input-to-output electric strength tests should not be repeated in the field. Power-One will not honor any warranty claims resulting
from electric strength field tests.
EMC Specifications
Input Specifications
Specification is valid for input voltage, load, and temperature ranges, unless otherwise stated.
1
1
Input voltage
Input frequency
Turn-on input voltage
Turn-off input voltage
Inrush current limitation
Hold-up time
Power factor
Efficiency
Max input current
Input connector
87% for FNP1500-12
Agency approvals
Insulation safety rating
Electric strength test voltage
Electrostatic discharge
Electromagnetic field
Electrical fast transients/burst
Surge
Voltage dips and interruptions
RF conducted immunity
Emissions conducted
Emissions radiated
Harmonics
Voltage fluctuation and flicker
Voltage sag
Subassemblies are pre-tested with 4.2 kVDC in accordance with EN50116 and IEC/EN60950.
Parameter
Parameter
Parameter
After last AC line peak ,V
115/230 VAC acc. ETS 300 132-1
V
i
= 230 VAC, I
SEMI F47-0200 (High Line 230V)
Conditions/description
CISPR 22/EN 55022/EN 61204
CISPR 22/EN 55022/EN 61204
UL60950, (UL) CSA 60950 (cUL),
EN 60950(TÜV), CE Mark for LVD
IEC/EN 61000-4-2, level 4
IEC/EN 61000-4-3, level 3
IEC/EN 61000-4-4, level 3
IEC/EN 61000-4-5, level 3
Ramping down
Conditions/description
Ramping up
IEC/EN 61000-4-11
V
IEC/EN 61000-4-6
IEC/EN 61000-3-2
IEC/EN 61000-3-3
< 100 ms
Output 1 to output 2
i nom
Page 3 of 17
Description
Output to case
Output to case
Input to output
Input to output
16A – 20 A / 250 VAC; according to IEC320 C19
Input to case
Input to case
, I
o nom
o nom
i
, T
= 230 VAC, P
C
= 25 °C
& FNR-3 Power Shelves Data Sheet
o nom
FNP1500/1800 Front-Ends
0.95
Min
89
85
47
79
70
20
1
2.12
Min
4.2
0.5
0.1
Performance criterion B or better
1
10 VAC, AM 80 %, 1 kHz
Performance criterion B
Performance criterion A
Performance criterion B
Performance criterion B
Performance criterion A
50/60
Nom
230
Reinforced
Functional
90
Basic
Nom
Criterion
Class B
Class A
Class B
Pass
Pass
Max
264
63
85
78
50
20
Max
W/VA
VAC
VAC
VAC
Unit
A
kVDC
kVDC
kVDC
kVDC
A
ms
Hz
%
Unit
rms
pk