S8E3-05031D Omron, S8E3-05031D Datasheet - Page 8

POWER SUPPLY 50W 3OUT W/COVER

S8E3-05031D

Manufacturer Part Number
S8E3-05031D
Description
POWER SUPPLY 50W 3OUT W/COVER
Manufacturer
Omron
Series
S8E3r
Datasheet

Specifications of S8E3-05031D

Voltage - Output
5V, ±12V
Number Of Outputs
3
Power (watts)
50W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 132VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 5A
2nd Output
12 VDC @ 1.5A
3rd Output
-12 VDC @ 500mA
Size / Dimension
7.62" L x 2.71" W x 1.3" H (193.5mm x 69mm x 33mm)
Power (watts) - Rated
50W
Operating Temperature
-10°C ~ 55°C
Efficiency
73%
Approvals
CSA, UL
Product
Switching
Output Power Rating
25 W
Output Voltage (channel 1)
5 V
Output Current (channel 1)
5 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
1.5 A
Dimensions
6.77 mm L x 2.71 mm H
Lead Free Status / RoHS Status
Request inventory verification / Request inventory verification
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8E305031D
Z1162
20521 (/(&7521,&6 //&


Cat No. GC PS6
Precautions
J MOUNTING
Two (or More) Power Supplies Mounted Side-by-Side
When mounting two or more Power Supplies side-by-side, allow
at least 20 mm spacing between them, as shown in the following
illustration.
To improve and maintain the reliability of the Power Supply
over a long period of time, mount the Power Supply so that air
flow takes place around the Power Supply. The Power Supply
is designed to dissipate heat through natural air-flow.
Forced-air cooling is recommended.
20 mm min.
2/03
20521 &$1$'$ ,1&

Specifications subject to change without notice
Mounting Screws
When tightening the mounting screws into the power supply, do
not allow them to penetrate more than 4 mm into the power
supply.
Penetration of Metal Filings and Cuttings
If drilling and other work is carried out over the power supply,
metal filings, cuttings, and other materials may fall onto the
printed circuit boards inside the power supply, leading to internal
shorts and damage. If it is necessary to work over top of the
power supply, cover the power supply with a sheet or other
suitable material to prevent the entry of foreign matter into the
power supply. This step is necessary even if the power supply is
equipped with a cover. After completing the above work and
before supplying power, remove the sheet to avoid interference
with appropriate cooling.
Switching Power Supply
20521 21/,1(
S8E3
Printed in USA
8