S8PS-05024CD Omron, S8PS-05024CD Datasheet - Page 2

POWER SUPPLY 24V 2.1A DIN RAIL

S8PS-05024CD

Manufacturer Part Number
S8PS-05024CD
Description
POWER SUPPLY 24V 2.1A DIN RAIL
Manufacturer
Omron
Series
S8PSr
Datasheet

Specifications of S8PS-05024CD

Power Supply Type
Switching (Closed Frame)
Voltage - Output
24V
Number Of Outputs
1
Power (watts)
50W
Applications
Commercial
Voltage - Input
85 ~ 264VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 2.1A
Size / Dimension
5" L x 1.57" W x 3.35" H (127mm x 40mm x 85mm)
Power (watts) - Rated
50W
Operating Temperature
-10°C ~ 55°C
Efficiency
80%
Approvals
CSA, EN, UL, VDE
No. Of Outputs
1
Output Voltage
24V
Output Current
2.1A
Power Rating
50W
Input Voltage
85V AC To 264V AC
Output Type
Fixed
Output Current 1
2.1A
Output Power
50W
Product
Switching
Output Power Rating
50 W
Output Voltage (channel 1)
24 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8PS05024CD
Z1175
Specifications
■ Ratings/Characteristics
Note: 1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
Efficiency (typical)
Input
Output
Additional
function
Other
2. A 100% load for rated input voltage (100 VAC or 200 VAC).
3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than 10% of the voltage adjustment range. When ad-
4. The output will shut off and the protection-ON alarm indicator will simultaneously light. Turn OFF the input power supply, wait 1 min., and
5. Turn OFF the input power supply, wait 1 min., and then turn ON the input power to recover normal operation. (For 300-W and 600-W
6. The weight indicated is for a front-mounting open-frame model. (includes the cover for 300-W and 600-W front-mounting models.)
temperature of the Power Supply may result in ignition or burning.
justing the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
then turn ON the input power supply to recover normal operation.
models, the output will shut off and the protection-ON indicator will simultaneously light.)
Voltage (See note 1.)
Frequency (See note 1.)
Current (See note 2.)
Leakage current (See note 2.)
Inrush current (See note 2.)
Power factor (See note 2.)
Harmonic current standards
Voltage adjustment range (See note 3.)
Ripple (See note 2.)
Input variation influence
Load variation influence
Temperature variation influence (See note 2.) 0.05%/°C max.
Startup time
Hold time (See note 2.)
Overload protection
Overvoltage protection (See note 5.)
Overheat protection
Protection-ON alarm indicator
Parallel operation
Heat radiation
Ambient operating temperature
Storage temperature
Ambient operating humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
EMI
EMS
Approved standards
Weight (See note 6.)
Mounting method
http://www.ia.omron.com/
Item
200-V input
200-V input
200-V input
Conducted
UL
100-V input
100-V input
100-V input
Emission
(See note 2.)
Radiated
Emission
cUL
cUR
EN/VDE
74% to 80% (depends on the model)
100 to 240 VAC (85 to 264 VAC)
50/60 Hz (47 to 63 Hz)
0.9 A max.
0.45 A max.
0.5 mA max.
1.0 mA max.
25 A max. (for a cold start at 25°C)
50 A max. (for a cold start at 25°C)
0.95 typical
Based on EN
61000-3-2
−5% to 10%
2% (p-p) max.
0.4% max. (at 85 to 132 VAC input/at 170 to 264 VAC input, 100% load)
0.8% max. (with rated input, 0 to 100% load)
1,000 ms max. (up to 90% of output voltage at rated out-
put voltage/current)
20 ms min.
105% min., voltage drop, intermittent operation
(With the 600-W model, output is turned OFF at 5 s min.)
Yes
No
No
No
Natural air-cooling
Refer to the derating curve in Engineering Data (with no icing or condensation).
−25 to 65°C
Yes (color: green)
Conforms to EN61204-3 EN55011 Class B and based on FCC Class B
Conforms to EN61204-3 EN55011 Class B
Conforms to EN61204-3 High severity levels
UL508, UL1012, UL60950-1
CSA C22.2 No. 14
CSA No. 60950-1
EN50178 (=VDE0160), EN60950-1 (=VDE0805 Teil 1)
420 g max.
Front Mounting Bracket or DIN Rail Mounting Bracket
25% to 85%
3.0 kVAC for 1 min. (between all inputs and outputs)
2.2 kVAC for 1 min. (between all inputs and PE terminal)
1.0 kVAC for 1 min. (between all outputs and PE terminal)
100 MΩ min. (between all outputs and inputs/PE terminal at 500 VDC)
10 to 55 Hz, 0.75-mm amplitude for 2 h each in X, Y, and Z directions
300 m/s
50 W
2
, 3 times each in ±X, ±Y, and ±Z directions
1.8 A max.
0.9 A max.
Complies with EN 61000-3-2
600 g max.
100 W
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
2.7 A max.
1.4 A max.
735 g max.
150 W
5.4 A max.
2.7 A max.
1,500 ms max.
Yes (color: red)
Yes, 2 units max.
2,200 g max.
300 W
10 A max.
5 A max.
Yes
Built-in fan
3,500 g max.
Front Mounting Bracket
600 W
S8PS
2