RWS-30A-24/A TDK Corporation, RWS-30A-24/A Datasheet

POWER SUP 30W 24V 1.25A ENCLOSED

RWS-30A-24/A

Manufacturer Part Number
RWS-30A-24/A
Description
POWER SUP 30W 24V 1.25A ENCLOSED
Manufacturer
TDK Corporation
Series
RWSr
Datasheets

Specifications of RWS-30A-24/A

Voltage - Output
15V
Number Of Outputs
1
Power (watts)
30W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 1.3A
Size / Dimension
4.78" L x 1.38" W x 3.82" H (121.5mm x 35mm x 97mm)
Power (watts) - Rated
30W
Operating Temperature
0°C ~ 60°C
Efficiency
71%
Approvals
CE, CSA, DENTORI, EN, UL
3rd Output
-
2nd Output
-
4th Output
-
Other names
285-1041
RWS-30A-24A
RWS30A-24A
RWS30A24/A
*10. At vertical mounting.
*11. Refer to instruction manual for testing procedure.
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. At 100VAC and maximum output power, Ta=25°C.
*2. For cases where conformance to various safety specs
*3. At 100VAC or 200VAC & maximum output power.
*4. Typical value on cold start, Ta=25°C.
*5. From 85 ~ 265VAC or 110 ~ 330VDC constant load.
*6. From No load ~ Full load, constant input voltage.
*7. Foldback current limiting with automatic recovery.
*8. Inverter shut-down method, manual reset.
*9. At 100VAC, nominal output voltage and maximum
10 Maximum Line Regulation
11 Maximum Load Regulation
12 Over Current Protection
13 Over Voltage Protection
14 Hold-up Time (Typ)
15 Remote Sensing
16 Series Operation
17 Operating Temperature
18 Operating Humidity
19 Storage Temperature
20 Storage Humidity
21 Cooling
22 Temperature Coefficient
23 Withstand Voltage
24 Isolation Resistance
25 Vibration
26 Shock
27 Safety
28 Conducted Radio Noise
29 Weight
30 Size (WxHxD)
1 Nominal Output Voltage
2 Maximum Output Current
3 Maximum Output Power
4 Efficiency (Typ)
5 Input Voltage Range
6 Input Current (Typ)
7 Inrush Current(Typ)
8 Output Voltage Range
9 Maximum Ripple & Noise
PA761-01-01C
ITEMS
(UL, CSA, EN) are required, to be described as
100 - 240VAC, 50/60Hz on name plate.
Avoid to operate over load or dead short for 30 seconds.
output current, Ta=25°C.
RWS 30A Specifications
MODEL
UL1950
CSA950
EN60950
DENTORI
(*10) -
(*11) - Input - Chassis : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
(*1) %
(*2) - 85 ~ 265VAC (47 ~ 440Hz) or 110 ~ 330VDC
(*3) - 0.65A at 100VAC or 0.35A at 200VAC
(*4) - 20A at 100VAC or 40A at 200VAC
(*5) mV
(*6) mV
(*7) A
(*8) V
(*9) -
mm 35 x 97 x 121.5 ( Refer to Outline Drawing )
mV
W
V
A
g 310
-
-
-
-
- -30 ~ +85°C
-
- Convection Cooled
- 1% (Typ) at 0°C ~ +50°C
- More than 100M at 25°C and 70%RH Output - FG : 500VDC
- 10 ~ 55Hz Amplitude (Sweep for 1min)
- Less than 20G
- Approved by UL
- Approved by C-UL
- Approved by TUV
- Built to meet ( Rated input voltage : 100VAC )
- Built to meet FCC-ClassB.
Output - Chassis : 500VAC (100mA) for 1min
Less than 2G X, Y, Z 1hour each.
±10%
0 ~ +50°C ( 100% ), +60°C ( 60% )
30 ~ 90%RH (No dewdrop)
10 ~ 95%RH (No dewdrop)
5.75 ~ 6.75
RWS30A
Possible
6.3 ~
20ms
120
30
72
20
40
-5
5
6
13.8 ~ 16.2
RWS30A
2.63 ~
150
100
-12
2.5
12
30
77
48
*:For delivery, contact to our sales office.
17.3 ~ 20.3
RWS30A
2.1 ~
100
150
120
-15
15
30
79
60
80
60
40
20
2
0
0
AMBIENT TEMPERATURE(°C)
(VERTICAL MOUNTING)
10
DERATING CURVE
27.6 ~ 32.4
RWS30A
1.37 ~
20
31.2
200
150
-24
1.3
24
81
96
NEMIC-LAMBDA
30
40
55.2 ~ 64.8
RWS30A
0.63 ~
28.8
300
192
250
-48
50
0.6
48
81
*
60

Related parts for RWS-30A-24/A

RWS-30A-24/A Summary of contents

Page 1

... RWS 30A Specifications PA761-01-01C MODEL ITEMS 1 Nominal Output Voltage 2 Maximum Output Current 3 Maximum Output Power 4 Efficiency (Typ) 5 Input Voltage Range 6 Input Current (Typ) 7 Inrush Current(Typ) 8 Output Voltage Range 9 Maximum Ripple & Noise 10 Maximum Line Regulation 11 Maximum Load Regulation 12 Over Current Protection ...

Page 2

... RWS 30A OUTPUT DERATING OPEN FLAME (NO COVER) Ta(°C) MOUNTING : + WITH COVER (OPTION) Ta(°C) MOUNTING : + OUTPUT DERATING CURVE ( Open flame type : No cover ) 100 Ambient Temperature ( °C ) MOUNTING : A MOUNTING : B (STANDARD MOUNTING) LOAD(%) MOUNTING : B 100 100 100 100 100 100 100 100 60 60 LOAD(%) ...