FE-2000-48-RA TDK Corporation, FE-2000-48-RA Datasheet - Page 5

no-image

FE-2000-48-RA

Manufacturer Part Number
FE-2000-48-RA
Description
PWR SUP 48V 2000W 48A RACK MOUNT
Manufacturer
TDK Corporation
Series
FEr
Datasheet

Specifications of FE-2000-48-RA

Voltage - Output
48V
Number Of Outputs
1
Power (watts)
2000W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
170 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 42A
Power (watts) - Rated
2000W
Operating Temperature
-40°C ~ 70°C
Efficiency
79%
Approvals
CE, CSA, IEC, EN, TUV, UL
Line Regulation
1%
Size / Dimension
-
3rd Output
-
2nd Output
-
4th Output
-
Other names
Q932834
LAMBDA ELECTRONICS
FEATURES (CONT’D)
IV. PROTECTION FEATURES
OVERCURRENT
PROTECTION
OVERVOLTAGE
PROTECTION
THERMAL PROTECTION
(OVERTEMPERATURE
PROTECTION)
ISOLATION VOLTAGES
LEAKAGE CURRENT (AC
LINE TO CHASSIS GROUND)
REGULATORY AGENCY
COMPLIANCE
V. MECHANICAL FEATURES
STORAGE TEMPERATURE
(NON-OPERATING)
OPERATING TEMPERATURE
WEIGHT (NET)
WEIGHT (SHIP)
SIZE (L x W x H)
FINISH
MOUNTING
VI. OTHER FEATURES
COOLING
FUNGUS INERT
AUXILIARY-BIAS POWER
SUPPLY
ISOLATION DIODES
GUARANTEE
SPECIFICATION
DESCRIPTION
DESCRIPTION
515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 • TEL: 516-694-4200 • 516-293-0519
OUTPUT CURRENT IS LIMITED TO APPROXIMATELY 110 PERCENT OF 50ºC
RATED POWER FROM V
CHARACTERISTICS WILL PROVIDE FOLDBACK TO APPROXIMATELY 80
PERCENT OF RATED CURRENT BELOW V
INVERTER SHUTDOWN, NON-LATCHING. CONSULT FACTORY FOR
ADJUSTMENT.
SELF-RESETTING INVERTER SHUTDOWN.
3000VAC, INPUT TO OUTPUT
500VDC, OUTPUT TO CHASSIS GROUND
1500VAC, INPUT TO CHASSIS GROUND
LESS THAN 3.5mA WHEN OPERATED AT 250VAC (47-63Hz) OR LOWER
VOLTAGES.
FE SERIES POWER MODULES ARE COMPLAINT TO THE FOLLOWING
STANDARDS:
FORCED AIR, FAN COOLED FROM THE FRONT OF THE MODULE EXITING
THE REAR.
ALL FE POWER MODULES ARE INHERENTLY FUNGUS INERT.
12VDC AT 50mA SOURCE REFERENCED TO -V
EXTERNAL HOUSEKEEPING CIRCUITRY.
AVAILABLE SOLELY ON -RA MODULES. BUILT IN OR-ING DIODES IN THE -
V
THE DC BUSS IN THE CASE OF POWER SUPPLY FAILURE. REVERSE
LEAKAGE CURRENT IS LESS THAN 8mA.
TWO YEARS FROM THE TIME OF DELIVERY, PARTS AND LABOR.
OUT
INCHES
UL1950
CSA 22.2-234
EN60950
CE MARKED FOR EUROPEAN COMMUNITY COMPLIANCE
UNITS
LAMBDA ELECTRONICS INCOPORATED
LBS
LBS
ºC
ºC
TERMINAL PROVIDE A SINGLE POINT FAILURE RIDE-THROUGH FOR
I
NSTRUCTION
EITHER STAND-ALONE OR ASSEMBLED INTO A STANDARD
LAMBDA MODEL NO. FE6K RACKING SYSTEM.
P. 5
FE2000-24
OUTMAX
OPERATIONAL DEFINITION
-40 TO +70 WITH DERATING ABOVE +50
(-40 OPERATION REQUIRES A THIRTY
TO V
MINUTE WARM-UP PERIOD)
M
DEFINITION
ANUAL
OUTMIN
11.97 x 4.87 x 5.50
-40 TO +85
. CURRENT LIMIT
BLACK
OUTMIN
10.00
9.00
OUT
.
TERMINAL FOR
FE2000-48
FE2000 SERIES
IMFE2000

Related parts for FE-2000-48-RA