HSC-5-6-OVP TDK Corporation, HSC-5-6-OVP Datasheet

no-image

HSC-5-6-OVP

Manufacturer Part Number
HSC-5-6-OVP
Description
PWR SUP 5V 30.0W 6.0A SNG OUT
Manufacturer
TDK Corporation
Series
Hr
Datasheets

Specifications of HSC-5-6-OVP

Voltage - Output
5V
Number Of Outputs
1
Power (watts)
30W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
100, 120, 220, 230, 240VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 6A
Size / Dimension
5.63" L x 4.88" W x 2.48" H (143mm x 124mm x 63mm)
Power (watts) - Rated
30W
Operating Temperature
0°C ~ 70°C
Efficiency
45%
Approvals
CE, EN, UL
Line Regulation
±0.05%
Load Regulation
±0.05%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
HSC56OVP
H F e a t u r e s a n d B e n e f i t s
Feature
S p e c i f i c a t i o n s
ITEMS
AC Input
Efficiency
Transient Response
EMI
Output Adjustment
Remote Sense
Line Regulation
Load Regulation
Ripple and Noise
Overcurrent Protection
Overvoltage Protection
Cooling
Operating Temp. Range
Storage Temperature
Temperature coefficient
Humidity
Leakage Current
Vibration
Shock
Safety Agency Approval
Size
Warranty
Note: See Installation Manual for full details, test methods of parameters and application notes
Industry standard footprint
Low Output Ripple
Tight regulation
Operation up to 70C Ambients
Obsolete
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
uA
°C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
On all single output models, HDC12 & HDC15, and output 1 of triple output models
100/120/220/230/240VAC, 47-63Hz (derate by 10% for 50Hz operation)
Standard on 5V outputs set at 6.2V ±0.4V OVP12 module sold separately
Foldback with automatic recovery (Contact factory before adjusting)
±5% for all outputs (except outputs 2 & 3 on triple output models)
0 to +70°C, derate 3%/°C above 50°C
Benefit
for other outputs (see model selector)
Test & Measurement
Low noise applications
Light Industrial
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
UL60950-1, EN60950-1, CE Mark
Availability to second source
Reduced system interference
Better performance in sensitive equipment
Easier system integration
5V: 45%, 12/15V: 55%, 24V: 60%
FCC Class B, VDE0871 Level B
±0.05% for 50% load change
5 - 95% RH (non condensing)
±0.05% for 10% line change
MIL-STD-810C, Method 514
MIL-STD-810C, Method 516
Low Output Ripple
Single and Multiple Outputs
Excellent Line & Load Regulation
Worldwide Voltage Taps
Please see outline drawings
50us for 50% load change
Low Cost Linear Power Supplies
Convection or forced air
<3mV peak to peak
±0.01% per °C
-55 to +85°C
Two years
H Series
<50uA
Burn-in & Test, Automated
Test, Instrumentation,
Measurement, Detection
37

Related parts for HSC-5-6-OVP

HSC-5-6-OVP Summary of contents

Page 1

Feature Industry standard footprint Low Output Ripple Tight regulation Operation up to 70C Ambients ...

Page 2

... DIMENSIONS: MODEL 28 2.0 56.0 HSB A 28 3.0 84.0 HSC B 28 4.0 112.0 HSN C 1.0/0.8 24.0 1.0/0.8 HSD I 1.8/1.5 40.0 HDA H 1.8/1.5 HDB D 12* 3.4 80.0 HDC I 12* 3.4 HTC ...

Related keywords