BLP40-3000G POWER ONE, BLP40-3000G Datasheet - Page 3

no-image

BLP40-3000G

Manufacturer Part Number
BLP40-3000G
Description
PWR SUP 40W 5V,12V,-12V OUT TRPL
Manufacturer
POWER ONE
Series
BLP40r
Datasheet

Specifications of BLP40-3000G

Voltage - Output
5V, ±12V
Number Of Outputs
3
Power (watts)
40W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
100 ~ 250VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 5A
2nd Output
12 VDC @ 3A
3rd Output
-12 VDC @ 1A
Size / Dimension
3" L x 5" W x 1.23" H (76.2mm x 127mm x 31.2mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 70°C
Efficiency
70%
Approvals
CB, CE, EN, IEC, UL
Line Regulation
±2%, ±5%
Load Regulation
±2%, ±5%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Other names
179-2273
Environmental Specifications
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Forced-Air Cooling
Convection Cooling
Temperature Coefficient
Relative Humidity
Shock
Vibration
NOTES:
MCD10027 Rev. 1.0
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Ground Continuity
Dielectric Withstand Voltage
Electromagnetic Interference
ESD
Flicker
Radiated Susceptibility
EFT/Burst
Input Transient Protection
RF Immunity
Magnetic Fields
Leakage Current
1) 10 CFM or 150 LFM (average measurement of six equally-distanced points through a 3.5” x 1.6” cross-sectional area) with power supply mounted
on 0.25” standoffs. Recommended airflow direction is from the AC side to the DC side.
CONDITIONS/DESCRIPTION
Operating.
Non-Operating.
0 °C to 70 °C with linear derating to 50% above 50 °C. Unit will start up at
-20 °C, but will not meet all published specifications.
Forced-air cooling of 150 LFM at 10 CFM is required for full output power.
(See Model Selection Table).
When unit is mounted horizontally with free-air convection.
(See Model Selection Table).
0 °C to 70 °C (after 15-minute warm-up).
Non-Condensing @ 40 °C
Operating: half-sine 11 ±3ms, 3 axis.
Non-operating: half-sine 11±3ms, 3 axis.
Operating: Random vibration, 5-500 Hz (10 minutes each axis).
Non-operating: Random vibration, 5-500 Hz (10 minutes each axis).
CONDITIONS/DESCRIPTION
UL60950-1/CSA 22.2 No. 60950-1-03.
EN 60950-1/IEC 60950-1.
CB Approval.
CE Mark for LVD.
Input-to-Ground (Basic).
Input-to-Ouput (Reinforced). The primary to secondary test is not performed
Output-to-Ground (Functional).
FCC Part 15.
CISPR 22 and CISPR 11.
Per EN61000-4-2, level 3.
Per EN61000-3-3.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
Per EN61000-4-5, class 3.
Per EN61000-4-6, level 3.
Per EN61000-4-8.
Per EN60950.
on completed assemblies.
BLP40-1XXX
BLP40-3XXX
Page 3 of 5
BLP40 AC-DC Series Data Sheet
Line-to-Ground:
Line-to-Line:
AT 264 VAC:
At 264 VAC:
Conducted:
Conducted:
(NOTE 1)
1500
2121
3000
4242
500
MIN
MIN
-40
0
5
B
B
1
1
2
BLP40-3003
Pending Approval.
±0.02
NOM
NOM
25
3
3
1
www.power-one.com
0.48
0.72
MAX
MAX
10k
50k
2.4
6.0
70
85
25
95
15
40
40
40 Watts
ASL Ft.
ASL Ft.
Grms
Grms
UNITS
%/°C
%RH
UNITS
Class
VDC
VDC
VDC
VAC
VAC
V/m
V/m
A/m
mA
°C
°C
kV
kV
W
G
A

Related parts for BLP40-3000G