412-59586-G POWER ONE, 412-59586-G Datasheet - Page 3

COVER FOR MAP130 SERIES

412-59586-G

Manufacturer Part Number
412-59586-G
Description
COVER FOR MAP130 SERIES
Manufacturer
POWER ONE
Series
MAP130r
Type
Coversr
Datasheet

Specifications of 412-59586-G

Accessory Type
Cover
Product
Kits
For Use With/related Products
Power One MAP130 Series Power Supplies
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
179-2297
Interface Signals and Internal Protection
PARAMETER
Overvoltage Protection
Overcurrent Protection
Remote Sense
Power Fail Warning
Overtemperature Warning
NOTES: 1) Power Fail not available on MAP130-1012 and MAP130-1024.
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic
Interference,
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
Insulation Resistance
Leakage Current
NOTES: 1) MAP130-1005 meets Class A, radiated.
Environmental Specifications
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
Options
DESCRIPTION
Cover
MCD10115 Rev. 1.3, 05-Feb-10
(Note 1)
(Note 2)
2) MAP130-1012 and MAP130-1024 have overtemperature protection, but do not have the warning feature.
2) MAP130-1005, MAP130-4003, and MAP130-4010, meet level 2, ±1kV.
CONDITIONS/DESCRIPTION
Provided on single output units and only
the main output of multiple output units.
All models have inherent short circuit protection. Units will automatically restart at the removal of the fault.
Total voltage compensation for main output cable losses.
Logic LO (denotes power fail detected).
Logic HI with internal pull-up to output.
Power Fail trip point, maximum load, decreasing line.
Time before regulation dropout, at full load, due to loss of input power.
Warning prior to system shutdown due to excessive internal temperatures.
Shifts Power Fail signal to a logic LO state.
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TÜV).
Input to Output, 1 second.
FCC CFR title 47 Part 15 Sub-Part B - Conducted
EN55022 / CISPR 22 Conducted
EN55022 / CISPR 22 Radiated (Note 1)
Per EN61000-4-2, level 4
Per EN61000-4-3, level 3
Per EN61000-4-4, level 3 (Note 2)
Per EN61000-4-5 class 3
Input to output
Per EN60950 (264 VAC)
CONDITIONS/DESCRIPTION
Operating
Non-Operating
Derate linearly above 50°C by 2.5% per °C
0°C to 70°C (after 15 minute warm-up period)
Non-Condensing
Operating, peak acceleration
Random vibration, 10Hz to 2kHz, 3 axis
NOTES
Add ‘C’ suffix to model number or order part number 412-59586-G separately.
For convection cooled applications with covers, derate output power as follows:
Derate all multiple output models and MAP130-1005 to 120 watts.
Derate MAP130-1012 and MAP130-1024 to 140 watts.
Page 3 of 4
MAP130 AC-DC Series Data Sheet
All other models.
MAP130-1012
MAP130-1024
MAP130-4004
Line to Line
Line to Ground 2
At 100% load:
At 50% load:
17.0
32.0
2600
6.2
5.5
MIN
MIN
MIN
-40
86
20
10
±2
5
B
B
B
8
1
7
0
5
(215.9mm x 114.3mm x 61.0mm)
±0.02
NOM
NOM
NOM
8.50" x 4.50" x 2.40"
10
Approved
www.power-one.com
DIMENSIONS
±0.05
22.0
37.0
10K
40K
MAX
250
MAX
700
MAX
7.4
6.8
0.7
94
50
70
85
95
20
6
UNITS
UNITS
Class
UNITS
%/°C
%RH
G
VDC
VAC
VDC
V/M
M
Feet
mV
mS
mS
G
k
µA
kV
kV
kV
°C
°C
°C
RMS
V
PK

Related parts for 412-59586-G