VHK50W-Q48-S12 CUI Inc, VHK50W-Q48-S12 Datasheet

CONVERTER DC-DC 12V 4.16A 50W

VHK50W-Q48-S12

Manufacturer Part Number
VHK50W-Q48-S12
Description
CONVERTER DC-DC 12V 4.16A 50W
Manufacturer
CUI Inc
Series
V-Infinity VHK50Wr
Type
Isolatedr
Datasheet

Specifications of VHK50W-Q48-S12

Output
12V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Chassis Mount
Voltage - Input
18 ~ 75V
Package / Case
Module
1st Output
12 VDC @ 4.16A
Size / Dimension
4.23" L x 4.01" W x 1.50" H (107.5mm x 101.8mm x 38mm)
Power (watts) - Rated
50W
Operating Temperature
-40°C ~ 85°C
Efficiency
83%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
102-1827
PART NUMBER: VHK50W
MODEL
VHK50W-Q24-S3R3
VHK50W-Q24-S5
VHK50W-Q24-S12
VHK50W-Q24-S15
VHK50W-Q24-S24
VHK50W-Q24-S28
VHK50W-Q24-S48
VHK50W-Q48-S3R3
VHK50W-Q48-S5
VHK50W-Q48-S12
VHK50W-Q48-S15
VHK50W-Q48-S24
VHK50W-Q48-S28
VHK50W-Q48-S48
notes:
INPUT
parameter
input voltage range
under voltage lockout
remote on/off control
input filter
notes:
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-
date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair
or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty.
description
The VHK50W series of rugged DC-DC
converters are designed for high
reliability applications, featuring integral
heat sink, over-temperature protection,
over-current protection and input
transient voltage protection. With an
external input fuse, the converter can
protect accidental input polarity reversal.
The wide 4:1 input range (9-36V or 18-
75V) is very useful to stabilize an input
source like batteries in various
discharging and charging conditions.
Additionally, high efficiency, fast
response, tight regulations, remote sense
and remote On/Off control make these
converters very useful in many industrial
and communications applications.
20050 SW 112
4
th
1. see output derating curves (page 4)
2. input currents are measured at nominal input voltage
3. efficiency is measured at nominal line, full load
4. add suffix “N” to the model number for negative logic on/off control
Ave. Tualatin, Oregon 97062
conditions/description
24 Vin power up
24 Vin power down
48 Vin power up
48 Vin power down
section 15 in the application notes
PI type
nominal
(V dc)
24
24
24
24
24
24
24
48
48
48
48
48
48
48
input voltage
features
·25-50W isolated output
·Efficiency to 83%
·RoHS Compliant
·4:1 input range
·Regulated output
·Continuous short circuit
·Metal enclosure with integrated
·Rugged design
·Over-temperature shutdown
protection
heatsink
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
9.0~36.0
9.0~36.0
9.0~36.0
9.0~36.0
9.0~36.0
9.0~36.0
9.0~36.0
(V dc)
range
phone
phone 503.612.2300 fax
DESCRIPTION: chassis mount dc-dc converter
voltage
output
(V dc)
3.3
3.3
12
15
24
28
48
12
15
24
28
48
5
5
min
18
9
current
output
fax 503.612.2383
4.16
3.33
2.08
1.78
1.04
4.16
3.33
2.08
1.78
1.04
(A)
10
10
10
10
nom
8.8
24
48
17
16
8
1
no load
max
(mA)
36
75
50
50
50
50
50
50
50
50
50
50
50
50
50
50
input current
2
www.v-infinity.com
full load
1833
2637
2537
2538
2537
2537
2537
1302
1267
1265
1264
1264
1253
(mA)
905
rev.
page
date
page
date
units
V dc
V dc
V dc
V dc
V dc
V dc
2
08/2009
1 of 11
efficiency
typ.
(%)
75
79
82
82
82
82
82
76
80
83
83
83
83
83
3

Related parts for VHK50W-Q48-S12

VHK50W-Q48-S12 Summary of contents

Page 1

... MODEL VHK50W-Q24-S3R3 VHK50W-Q24-S5 VHK50W-Q24-S12 VHK50W-Q24-S15 VHK50W-Q24-S24 VHK50W-Q24-S28 VHK50W-Q24-S48 VHK50W-Q48-S3R3 VHK50W-Q48-S5 VHK50W-Q48-S12 VHK50W-Q48-S15 VHK50W-Q48-S24 VHK50W-Q48-S28 VHK50W-Q48-S48 notes: 1. see output derating curves (page 4) 2. input currents are measured at nominal input voltage 3. efficiency is measured at nominal line, full load INPUT parameter conditions/description ...

Page 2

... PART NUMBER: VHK50W OUTPUT parameter conditions/description voltage accuracy transient response 25% step load change external trim adj. range ripple & noise (20MHz BW) 3.3V, 5V 12V& 15V 24V 28V 48V temperature coefficient short circuit protection continuous 5 line regulation 6 load regulation over voltage protection trip range nom. ...

Page 3

... B (TYP) 26.50 1.043 *DIN rail mounting kit available (part# VHK-DIN) PC FILE NAME: VHKXXW Series COPYRIGHT 2008 BY CUI INC. 107.5 4.232 38.0 1.496 18.75 0.738 B (2 PLCS) 70.0 2.756 5 B Terminal # Material Aluminum/Steel REV. DESCRIPTION A NEW DRAWING ...

Page 4

... APPLICATION NOTES 1. OUTPUT DE-RATING The operating ambient temperature range for VHK50W is -40 ~ +85°C, with the actual output power subject to the following de-rating curves at free-air convection and at forced air conditions. To ensure long-term reliability important to ensure proper cooling at the worst operating conditions. Please note the derating curves may improve if the converter is mounted on a metal surface to allow heat conduction ...

Page 5

... Ipeak = 150%*Pout/(η η *Vmin). In the previous example of VHK50W-Q24-S5, the peak input current at 9V was calculated to be 10.29A. A 10A or a 15A fuse may be suitable for this application. Make sure the fuse voltage rating is higher than the maximum input voltage. ...

Page 6

... R trim-down o, nom is the Where: R o,nom , nominal output voltage Table 1. For example, to trim-up the output voltage of 5.0V is calculated module (VHK50W-Q48-S5 4.6V, R trim-up = 11.2 (KΩ) Ω Ω 7.2 3.3 4.636 7.191 Table 2 6.977 173.7 13.3 phone 503.612.2300 fax phone 10KΩ ...

Page 7

... PART NUMBER: VHK50W 10. OUTPUT OCP AND SHORT-CIRCUIT PROTECTION Output overload and short circuit conditional will cause the output voltage to decline or shutdown altogether. is not over 85°C, the output recovers automatically when the short or OCP conditions are removed. In the case of slight overloading, the output voltage may not shut down, but the converter may build up heat over time, causing over-temperature shutdown. ...

Page 8

... PART NUMBER: VHK50W 14. OUTPUT SERIES CONNECTIONS Two or more converters can be connected in series to obtain a higher output voltage. To prevent output reverse biasing each other in case of a short, add a Schottky diode on each output in reverse polarity, as shown in the diagram. In the event of a short, the converters will forward-bias the diodes and the output reversal will be limited to one diode drop (about 0.5V) only not to damage the converters. The forward current will cause each converter to go into short-circuit protection. make sure that: 1) the diodes voltage rating is higher than each converter output ...

Page 9

... PART NUMBER: VHK50W 17. INPUT FILTERING AND EMI INTERFERENCE The VHK50W converters have input capacitors that control input current ripple and the associated EMI interference. However, it has not been tested to a formal standard for conducted emissions. Additional filtering may be needed to ensure compliance to an EMI standard ...

Page 10

... PART NUMBER: VHK50W FIGURE 10.2B. EMI FILTER FOR VHK50W (CLASS B) L1 +Vin C1 -Vin Note: Model No. C1 VHK50W-Q24-S28 100uF/50V KY VHK50W-Q48-S28 100uF/100V KY 100uF/100V 1000pF/2KV NC L1 FUSE TVS C1 EMI to meet class A C1 VHK50W-Q24-S48 NC VHK50W-Q48-S48 NC C1 EMI to meet class B 10uF/50V VHK50W-Q24-S48 X7R,2220 Ceramic 47uF/100V VHK50W-Q48-S48 KMF note: The recommended components are a starting point but not guaranteed for meeting these EMI requirements ...

Page 11

... PART NUMBER: VHK50W 18. OUTPUT FILTERING The converter has built-in capacitors at the output to control ripple and noise. If desired, additional output capacitance can be introduced at the input to the powered equipment. Recommended starting point: one 10μF tantalum and one 1μF ceramic capacitor in parallel at the output. ...

Related keywords