VHK100W-Q48-S48 CUI Inc, VHK100W-Q48-S48 Datasheet

CONVERTER DC/DC 48V 2.08A 100W

VHK100W-Q48-S48

Manufacturer Part Number
VHK100W-Q48-S48
Description
CONVERTER DC/DC 48V 2.08A 100W
Manufacturer
CUI Inc
Series
V-Infinity VHK100Wr
Type
Isolatedr
Datasheet

Specifications of VHK100W-Q48-S48

Output
48V
Number Of Outputs
1
Power (watts)
100W
Mounting Type
Chassis Mount
Voltage - Input
18 ~ 75V
Package / Case
Module
1st Output
48 VDC @ 2.08A
Size / Dimension
4.23" L x 4.01" W x 1.50" H (107.5mm x 101.8mm x 38mm)
Power (watts) - Rated
100W
Operating Temperature
-40°C ~ 85°C
Efficiency
85%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
102-1818
PART NUMBER: VHK100W
MODEL
VHK100W-Q24-S3R3
VHK100W-Q24-S5
VHK100W-Q24-S12
VHK100W-Q24-S15
VHK100W-Q24-S24
VHK100W-Q24-S28
VHK100W-Q24-S48
VHK100W-Q48-S3R3
VHK100W-Q48-S5
VHK100W-Q48-S12
VHK100W-Q48-S15
VHK100W-Q48-S24
VHK100W-Q48-S28
VHK100W-Q48-S48
notes:
INPUT
parameter
input voltage range
under voltage lockout
remote on/off control
input filter
notes:
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-
date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair
or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty.
description
The VHK100W series of rugged DC-DC
converters are designed for high
reliability applications, featuring integral
heat sink, over-temperature protection,
over-current protection and input
transient voltage protection. With an
external input fuse, the converter can
protect accidental input polarity reversal.
The wide 4:1 input range (10-36V or 18-
75V) is very useful to stabilize an input
source like batteries in various
discharging and charging conditions.
Additionally, high efficiency, fast
response, tight regulations, remote sense
and remote On/Off control make these
converters very useful in many industrial
and communications applications.
20050 SW 112
4
th
1. see output derating curves (page 4)
2. input currents are measured at nominal input voltage
3. efficiency is measured at nominal line, full load
4. add suffix “N” to the model number for negative logic on/off control
Ave. Tualatin, Oregon 97062
conditions/description
24 Vin power up
24 Vin power down
48 Vin power up
48 Vin power down
section 13 in the application notes
PI type
nominal
(V dc)
24
24
24
24
24
24
24
48
48
48
48
48
48
48
input voltage
features
·66-100W isolated output
·Efficiency to 87%
·RoHS Compliant
·4:1 input range
·Regulated output
·Continuous short circuit
·Metal enclosure with integrated
·Rugged design
·Over-temperature shutdown
protection
heatsink
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
9.0~36.0
9.0~36.0
9.0~36.0
9.0~36.0
9.0~36.0
9.0~36.0
9.0~36.0
(V dc)
range
phone
phone 503.612.2300 fax
DESCRIPTION: chassis mount dc-dc converter
voltage
output
(V dc)
3.3
3.3
12
15
24
28
48
12
15
24
28
48
5
5
min
18
9
current
output
fax 503.612.2383
4.17
3.57
2.08
4.17
3.57
2.08
(A)
8.3
6.7
8.3
6.7
20
20
20
20
nom
8.8
24
48
17
16
8
1
no load
max
(mA)
36
75
35
35
35
35
35
35
35
50
50
50
50
50
50
50
input current
2
www.v-infinity.com
full load
3438
5081
4940
4898
4905
4151
4952
1741
2465
2427
2421
2397
4151
2447
(mA)
rev.
page
date
page
date
units
V dc
V dc
V dc
V dc
V dc
V dc
2
08/2009
1 of 10
efficiency
typ.
85.5
84.5
85.5
86.5
(%)
80
82
84
85
86
84
79
87
86
85
3

Related parts for VHK100W-Q48-S48

VHK100W-Q48-S48 Summary of contents

Page 1

... VHK100W-Q24-S15 VHK100W-Q24-S24 VHK100W-Q24-S28 VHK100W-Q24-S48 VHK100W-Q48-S3R3 VHK100W-Q48-S5 VHK100W-Q48-S12 VHK100W-Q48-S15 VHK100W-Q48-S24 VHK100W-Q48-S28 VHK100W-Q48-S48 notes: 1. see output derating curves (page 4) 2. input currents are measured at nominal input voltage 3. efficiency is measured at nominal line, full load INPUT parameter conditions/description input voltage range under voltage lockout 24 Vin power up ...

Page 2

... PART NUMBER: VHK100W OUTPUT parameter conditions/description voltage accuracy transient response 25% step load change external trim adj. range ripple & noise (20MHz BW) 3.3V, 5V 12V& 15V 24V 28V 48V temperature coefficient short circuit protection continuous line regulation 5 6 load regulation over voltage protection trip range nom. ...

Page 3

... B (TYP) 26.50 1.043 *DIN rail mounting kit available (part# VHK-DIN) PC FILE NAME: VHKXXW Series COPYRIGHT 2008 BY CUI INC. 107.5 4.232 38.0 1.496 18.75 0.738 B (2 PLCS) 70.0 2.756 5 B Terminal # Material Aluminum/Steel REV. DESCRIPTION A NEW DRAWING ...

Page 4

... APPLICATION NOTES 1. OUTPUT DE-RATING The operating ambient temperature range for VHK100W is -40 ~ +85°C, with the actual output power subject to the following de-rating curves at free-air convection and at forced air conditions. To ensure long-term reliability important to ensure proper cooling at the worst operating conditions. Please note the derating curves may improve if the converter is mounted on a metal surface to allow heat conduction ...

Page 5

... Ipeak = 150%*Pout/(η η *Vmin). In the previous example of VHK100W-Q24-S12, the peak input current at 9V was calculated to be 19.61A. A 20A fuse may be suitable for this application. Make sure the fuse voltage rating is higher than the maximum input voltage. ...

Page 6

... R load R trim-up R (KΩ) is the Where: R o,nom , nominal output voltage Table 1. For example, to trim-up the output voltage of 5.0V is calculated module (VHK100W-Q48-S5 4.6V, R trim-up = 11.2 (KΩ) Ω Ω 3.168 7.2 5.8 8.2 19.656 13.304 Table 2 25.474 14.76 42.33 16.67 48.78 5 ...

Page 7

... PART NUMBER: VHK100W 10. OUTPUT OCP AND SHORT-CIRCUIT PROTECTION Output overload and short circuit conditional will cause the output voltage to decline or shutdown altogether. is not over 105°C, the output recovers automatically when the short or OCP conditions are removed. In the case of slight overloading, the output voltage may not shut down, but the converter may build up heat over time, causing over-temperature shutdown ...

Page 8

... PART NUMBER: VHK100W 14. OUTPUT SERIES CONNECTIONS Two or more converters can be connected in series to obtain a higher output voltage. To prevent output reverse biasing each other in case of a short, add a Schottky diode on each output in reverse polarity, as shown in the diagram. In the event of a short, the converters will forward-bias the diodes and the output reversal will be limited to one diode drop (about 0.5V) only not to damage the converters. The forward current will cause each converter to go into short-circuit protection. make sure that: 1) the diodes voltage rating is higher than each converter output ...

Page 9

... EN55022 class B VHK100W-Q24-S48 All other 24 V input models VHK100W-Q48-S48 All other 48 V input models 47 µF/100 V 47 µF/100 V note: The recommended components are a starting point but not guaranteed for meeting these EMI requirements. More or less filtering may be required for a specific application or to meet other EMI standards, e.g.MIL-STD-461 ...

Page 10

... For proper output ripple and noise measurement, connect a 10μF tantalum and a 1μF ceramic capacitor across the output. Set the scope bandwidth to 20MHz. Probe directly off of one of the capacitors, using a small ground clip to minimize measurement error. +Vin -Vin th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: chassis mount dc-dc converter FIGURE 10.3. EMI FILTER FOR VHK100W-XXX-S28 L1 +Vin C2 -Vin C2 47uF/50V KY 47uF/50V KY ...

Related keywords