Page 1
... Additionally, high efficiency, fast response, tight regulations, remote sense and remote On/Off control make these converters very useful in many industrial and communications applications. MODEL VHK200W-Q24-S12 VHK200W-Q24-S15 VHK200W-Q24-S24 VHK200W-Q24-S28 VHK200W-Q24-S48 VHK200W-Q48-S12 VHK200W-Q48-S15 VHK200W-Q48-S24 VHK200W-Q48-S28 VHK200W-Q48-S48 notes: 1 ...
Page 2
... PART NUMBER: VHK200W OUTPUT parameter conditions/description voltage accuracy 12V, 15V & 24V 28V & 48V transient response 25% step load change external trim adj. range ripple & noise (20MHz BW) 12V & 15V 24V 28V 48V temperature coefficient short circuit protection continuous 3 line regulation ...
Page 3
... B (TYP) 26.50 1.043 *DIN rail mounting kit available (part# VHK-DIN) PC FILE NAME: VHKXXW Series COPYRIGHT 2008 BY CUI INC. 107.5 4.232 38.0 1.496 18.75 0.738 B (2 PLCS) 70.0 2.756 5 B Terminal # Material Aluminum/Steel REV. DESCRIPTION A NEW DRAWING ...
Page 4
... APPLICATION NOTES 1. OUTPUT DE-RATING The operating ambient temperature range for VHK200W is -40 ~ +100°C, with the actual output power subject to the following de-rating curves at free-air convection and at forced air conditions. To ensure long-term reliability important to ensure proper cooling at the worst operating conditions. ...
Page 5
... PART NUMBER: VHK200W VHK200W-Q48 Power Derating Curves @ Nominal Input 120% 100% 80% 60% 40% 20 INPUT VOLTAGE RANGE It is important to ensure the input voltage measured at the converter input pins is within the range for that converter. Make sure wire losses and voltage ripples are accounted for. One possible problem is driving the converter with a linear unregulated power supply. ...
Page 6
... Ipeak = 150%*Pout/(η η *Vmin). In the previous example of VHK200W-Q24-S12, the peak input current at 10V was calculated to be 34.88A. A 35A or a 40A fuse may be suitable for this application. Make sure the fuse voltage rating is higher than the maximum input voltage. ...
Page 7
... R load R trim-down FIGURE 5: TRIM-UP VOLTAGE SETUP The value 100 is the Where: R o,nom nominal output voltage and C values are defined in Table 1. For example, to trim- down the 24V module (VHK200W-Q24-S24 25.92V, R Output A B Voltage(V) 12, 15, 5.11 511 24, 28V 48V 20 2000 phone phone 503 ...
Page 8
... PART NUMBER: VHK200W 10. OUTPUT OCP AND SHORT-CIRCUIT PROTECTION Output overload and short circuit conditional will cause the output voltage to decline or shutdown altogether. is not over 105°C, the output recovers automatically when the short or OCP conditions are removed. In the case of slight overloading, the output voltage may not shut down, but the converter may build up heat over time, causing over-temperature shutdown ...
Page 9
... INPUT FILTERING AND EMI INTERFERENCE The VHK200W converters have input capacitors that control input current ripple and the associated EMI interference. However, they have not been tested to a formal standard for conducted emissions. Additional filtering may be needed to ensure compliance to an EMI standard ...
Page 10
... VHK200W-Q24-S48 Class B 82uF/100V KY VHK200W-Q48-S5 Class B 82uF/100V KY VHK200W-Q48-S12 Class B 120uF/100V KY 120uF/100V KY 4.7uF/100V X7R 2220 1000pF/2KV 680pF/2KV VHK200W-Q48-S24 Class B 120uF/100V KY 120uF/100V KY 4.7uF/100V X7R 2220 1500pF/2KV 680pF/2KV VHK200W-Q48-S28 Class A 150uF/100V KY 150uF/100V KY VHK200W-Q48-S28 Class B 120uF/100V KY 120uF/100V KY 470uF/100V KY VHK200W-Q48-S48 Class A 100uF/100V KY 100uF/100V KY 100uF/100V KY VHK200W-Q48-S48 Class B 82uF/100V KY NOTE: The recommended components are a starting point but not guaranteed for meeting EMI requirements ...